![Festo CMXR-C2 Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/festo/cmxr-c2/cmxr-c2_assembly-and-installation-manual_2283148058.webp)
A. Technical appendix
58
Festo GDCP-CMXR-C2-HW-DE 1002NH
A.1.2
CMXR-C2, centralcontrol unit
Type
CMXR-C2
Dimensions (W x H x D)
[mm]
270 x 120 x 100
Product weight
[g]
1270
Control elements
CTRL key
Status displays
7-segment display
Power LED (green)
CPU data
400MHz processor, 256 MB DRAM
Serial interface
Connection technology
Transmission rate
Electrical isolation
[bit/s]
RS-232-C
Sub-D pin, 9-pin
1200 ... 115000, can be set via software
No
Fieldbus interface
Connection technology
Transmission rate
Electrical isolation
[kBit/s]
CAN bus
Sub-D pin, 9-pin
1000
No
USB interfaces
USB 2.0
Permanently allocated slot
Permanently allocated slot
Permanently allocated slot
Additional spare slot
1 slot for CAN optional module
1 slot for Ethernet optional module
1 slot for memory card (Compact Flash type 1)
1 slot for RS-232-C optional module
Ethernet
Connecting plug
Data transmission speed
Supported protocols
[Mbit/s]
RJ 45 (8-pin, socket)
10/100
TCP/IP
Programming, operating language
FCT (Festo Configuration Tool)
Table A.2 Technical data Central module CMXR
A.2
Accessories
Please select the appropriate accessories from our catalogue
A.3
Instructions on EMC-compliant wiring
The resistance to interference of an electrical system depends significantly on EMC-
compliant wiring and screening. Service practice shows that inadequate wiring and
screening of system components is frequently the cause of system faults and failures.
Содержание CMXR-C2
Страница 1: ...Controller Description Assembly and installation Type CMXR C2 Description 571 694 en 1002NH 751 509...
Страница 2: ......
Страница 5: ...Festo GDCP CMXR C2 HW EN 1002NH 5...
Страница 30: ...2 Assembly 30 Festo GDCP CMXR C2 HW EN 1002NH 1 End supports Fig 2 8 Securing the device with end supports 1 1...
Страница 56: ...6 Maintenance and care 56 Festo GDCP CMXR C2 HW EN 1002NH...