4. PLC interface MCP1
Festo GDCP-CMXR-F-EN 0909a
17
4.3.2
Control signals in the PROFIBUS data packet
MCP1-PB includes 12-byte control signals and 12-byte status signals, which are cyclically
exchanged. The signals are exchanged as I/O data packets on PROFIBUS.
Byte 1
Byte 2
Byte 3
Byte 4
CREG
CREG2
Unassigned
PRGNR
Control register 1
Control register 2
Program number
Byte 5
Byte 6
Byte 7
Byte 8
COVR
CJOG
EDATA1
EDATA2
Override
JOG register
8 input bits
8 input bits
Byte 9
Byte 10
Byte 11
Byte 12
JOGPOS
Target position of the JOG axis
Control register 1:
Bit
7
6
5
4
3
2
1
0
CREG1
WDBIT
QUITERR
WRREQU
HALTENA DRENA
JPENA
HAND
AUTO
Watchdog
bit
Acknow-
ledge
error
Request
control
sovereignty
Enable
HOLD
Enable
drives
Enable Jog
position
Manual
operation
mode
Automatic
operation
mode
Control register 2:
Bit
7
6
5
4
3
2
1
0
CREG2
LOAD
UNLOAD
START
STOP
UNAS-
SIGNED
UNAS-
SIGNED
DEVENA
EMSTOP
Load the
program
Unload
the
program
Start
program
Interrupt
program
Permis-
sion
button
Emergen-
cy off
Содержание CMXR-C1
Страница 2: ......