Parameters
Index.Subindex
Name
Data type
466
0x2166.07
Monitoring window speed standstill monitor-
ing
FLOAT32
467
0x2166.08
Monitoring window position standstill
FLOAT32
Tab. 314 Objects
5.8
Stop reached
Limit stop LS
The monitoring function combines standstill monitoring (STV) and current monitoring for the stop
detection. During this process, the actual current and speed values are monitored cyclically to check if
they have reached specified limits.
Timing
Status signal
LS
Stop detection
Initial state LS
= 0
The LS signal is set under the following conditions:
–
The actual current value exceeds the threshold value
–
AND STV = 1
–
AND both conditions are set to be longer than the damping time.
0
à
1
The LS signal is reset under the following conditions:
–
The actual current value falls below the threshold value.
–
OR STV = 0
1
à
0
Tab. 315 Status signals - Stop reached
Motion monitoring
329
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW
Страница 615: ......