Name
Description
Window
Monitoring window
Act
Actual value
Set
Setpoint
Tab. 294 Legend for Timing diagram: following error
5.3.1
CiA 402
Objects - Following error
Parameters
Index.Subindex
Name
Data type
Px.
CiA402: factor group is effective.
462
0x6066.00
Damping time position: following error
UINT16
463
0x6065.00
Monitoring window position: following error
UINT32
464
0x60F8.00
Monitoring window speed: following error
SINT32
4682
0x60F4.00
Current position: following error
SINT32
Px.
Manufacturer-specific objects: saved base unit for the object is effective.
462
0x2166.03
Damping time position: following error
UINT32
463
0x2166.04
Monitoring window position: following error
FLOAT32
464
0x2166.05
Monitoring window speed: following error
FLOAT32
4682
0x2166.42
Current position: following error
FLOAT32
4683
0x2166.43
Current velocity: following error
FLOAT32
4690
0x2166.4A
Damping time velocity: following error
FLOAT32
Tab. 295 Objects
5.4
Target area monitoring
Target monitor TMx
The function monitors the movement of the drive after reaching the target window (target reached =
TRUE). Depending on the operating mode, the position, speed or torque are monitored during this pro-
cess. The target area monitoring of a positioning command with a final speed is identical to the target
area monitoring of a speed command.
Timing
Status signal
TM…
Initial state
= 0
Motion monitoring
316
Festo — CMMT-ST-SW — 2019-02