Cell
Content/description
1
Range for CiA 402 objects: only the parameters that are allocated to an object of the
standard device profile for drives and motion controllers.
2
Range for manufacturer-specific objects: all parameters are allocated to an object in the
manufacturer-specific range
3
Parameter number
4
Allocated index and sub-index (hexadecimal)
5
Name of the parameter
6
Data type of the object; can differ from the data type of the parameter
Recomm. maximum
Tab. 86 Legend for the object table example
3.2.4
Measuring units
3.2.4.1
Defined measuring units
Basic units are defined measuring units in the servo drive controller that typically characterise physic-
al properties. These units cannot be changed by the user.
Size
Basic unit
Data type
Temperature
T
Degrees Celsius
°C
FLOAT32
Current
I
Ampere
A
FLOAT32
Voltage
r
Volt
V
FLOAT32
Energy
E
Joule/Watt second
J/Ws
FLOAT32
Torque
M
Newton-metre
Nm
FLOAT32
Resistance (electric)
R
Ohm
Ω
FLOAT32
Inductance
L
Henry
H
FLOAT32
Capacity (electric)
C
Farad
F
FLOAT32
Power
P
Watt
W
FLOAT32
Time
t
Second
s
FLOAT32
Value specification in per-
cent
%
—
—
FLOAT32
Tab. 87 Basic units
3.2.4.2
Configurable measuring units ("user unit")
Configurable units adapted to the respective application by the user are typically required for motion
variables. They generally refer to the output-side motion variables. The conversion of these user units
can be performed only in the "Pre-operational" state and requires a reinitialisation of the servo drive.
As a result, all pertinent parameters in the servo drive are converted to the new user unit. The control-
Product configuration
112
Festo — CMMT-ST-SW — 2019-02
Содержание CMMT-ST-SW