6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
57
Sub-index
01
h
Description
save_all_parameters
Access
rw
PDO Mapping
no
Units
--
Value Range
65766173
h
("save")
Default Value
1
If the default parameter set should also be taken over into the application parameter set,
the object
1010
h
_ 01
h
(
save_all_parameters
) must also be called up.
If the object is written via an SDO, the default behaviour is that the SDO is answered
immediately. The answer thus does not reflect the end of the storage process.
But the behaviour can be changed via the object
6510
h
_ F0
h
(
compatibility_control
).
6.2
Compatibility settings
6.2.1
Overview
In order to stay compatible with earlier CANopen implementations (e.g. also in other
device families) and still be able to make changes and corrections to the DSP402 and
DS301, the object
compatibility_control
was added. In the default parameter set, this
object delivers 0, that is, compatibility to earlier versions. For new applications, we
recommend setting the defined bits to permit the highest possible agreement with the
names standards.
6.2.2
Description of the Objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
6510_F0
h
VAR
compatibility_control
UINT16
rw
Objekt 6510
h
_ F0
h
: compatibility_control
Sub-index
F0
h
Description
compatibility_control
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
--
Value Range
0 … 1FF
h
, see table
Default Value
0