8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
161
Object 609A
h
: homing_acceleration
The object
homing_acceleration
determines the acceleration that is used during the
reference travel for all acceleration and braking processes.
Index
609A
h
Name
homing_acceleration
Object code
VAR
Data Type
UINT32
Access
rw
PDO Mapping
yes
Units
acceleration units
Value Range
--
Default Value
1000 min
-1
/s
Object 2045
h
: homing_timeout
The homing run can be monitored for its maximum execution time. The maximum
execution time can be specified with the object
homing_timeout
. If this time is exceeded
without the homing run being ended, error 11-3 is triggered.
Index
2045
h
Name
homing_timeout
Object code
VAR
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
ms
Value Range
0 (off), 1 … 65535
Default Value
60000