5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
99
Object 6410
h
_04
h
: iit_ratio_motor
Through the object iit_ratio_motor, the current extent of utilisation of the I
2
t limitation can be read in
thousandths.
Sub-Index
04
h
Description
iit_ratio_motor
Data Type
UINT16
Access
ro
PDO mapping
no
Units
thousandths
Value Range
–
Default Value
–
Object 6510
h
_38
h
: iit_error_enable
The object iit_error_enable establishes how the motor controller behaves when the I
2
t limitation oc
curs. Either it is only displayed in the status word, or error E 31-0 is triggered.
Index
6510
h
Name
drive_data
Object Code
RECORD
No. of Elements
51
Sub-Index
38
h
Description
iit_error_enable
Data Type
UINT16
Access
rw
PDO mapping
no
Units
–
Value Range
0, 1
Default Value
0
Value
Meaning
0
I
2
t error OFF
(Priority WARNING)
1
I
2
t error ON
(Priority CONTROLLER ENABLE OFF)
The error E 31-0 is activated by changing the error response. Reactions causing the drive to stop are
returned as ON, all others as OFF. When overwriting with 0, the error response WARNING is set; when
overwriting with 1, the error response CONTROLLER ENABLE OFF.