7
Operating modes
214
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Object 6071
h
: target_torque
This parameter is the entry value for the torque regulator in torque-regulated mode (Profile Torque
Mode). It is specified in thousandths of the nominal torque (object 6076
h
).
Index
6071
h
Name
target_torque
Object Code
VAR
Data Type
INT16
Access
rw
PDO mapping
yes
Units
motor_rated_torque/1000
Value Range
-32768 … 32768
Default Value
0
Object 6072
h
: max_torque
This value represents the motor's maximum permissible torque. It is specified in thousandths of the
nominal torque (object 6076
h
). If, for example, a 2-fold overloading of the motor is briefly permissible,
the value 2000 is entered here.
The object 6072
h
: max_torque corresponds with the object 6073
h
: max_current and may
not be overwritten until the object 6075
h
: motor_rated_current is overwritten with a valid
value.
Index
6072
h
Name
max_torque
Object Code
VAR
Data Type
UINT16
Access
rw
PDO mapping
yes
Units
motor_rated_torque/1000
Value Range
-1000 … 65536
Default Value
2023