7
Operating modes
212
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
7.7
Torque Regulation Operating Mode (Profile Torque Mode)
7.7.1
Overview
This chapter describes torque-regulated operation. This operating mode allows an external torque
setpoint value target_torque, which can be smoothed using the integrated ramp generator, to be spe
cified for the motor controller. It is thus possible for this motor controller to also be used for path con
trol, with which both the position controller and the speed regulator are displaced to an external com
puter.
target_torque (6071
h
)
Limit
Function
torque_profile_type (6088
h
)
controlword (6040
h
)
Trajectory
Generator
control effort
torque_slope (6087
h
)
motor_rated_torque (6076
h
)
max_torque (6072
h
)
motor_rated_torque (6076
h
)
Limit
Function
max_current (6073
h
)
motor_rated_current (6075
h
)
Limit
Function
control effort
max_current (6073
h
)
motor_rated_current (6075
h
)
motor_rated_current (6075
h
)
Torque
Control
and
Power
Stage
current_actual_value
(6078
h
)
torque_actual_value
(6077
h
)
torque_demand
(6074
h
)
DC_link_voltage
(6079
h
)
Motor
Fig. 7.12
Structure of torque-regulated operation