Operating modes
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
197
Sub-Index
01
h
Description
syncronize_on_group
Access
rw
PDO mapping
yes
Units
–
Value Range
0
Default Value
0
Value
Significance
0
Use standard SYNC telegram
Sub-Index
02
h
Description
ip_sync_every_n_event
Access
rw
PDO mapping
yes
Units
–
Value Range
1
Default Value
1
Object 60C4
h
: interpolation_data_configuration
Through the object record interpolation_data_configuration, the type (buffer_organisation) and size
(max_buffer_size, actual_buffer_size) of a possibly available buffer as well as access to this
(buffer_position, buffer_clear) can be configured. The size of a buffer element can be read out via the
object size_of_data_record. Although no buffer is available for the interpolation type “Linear interpola
tion without buffer”‚ access via the object buffer_clear must still be enabled in this case as well.
Index
60C4
h
Name
interpolation_data_configuration
Object Code
RECORD
No. of Elements
6
Sub-Index
01
h
Description
max_buffer_size
Data Type
UINT32
Access
ro
PDO mapping
no
Units
–
Value Range
0
Default Value
0