![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 193](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119193.webp)
7
Operating modes
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
193
7.4
Synchronous position specification (interpolated position mode)
7.4.1
Overview
The interpolated position mode (IP) permits specification of setpoint position values in a multi-axis
application of the motor controller. For this, synchronisation telegrams (SYNC) and position setpoints
are specified by a higher-order controller in a fixed time slot pattern (synchronisation interval). Since
the interval is normally greater than one position controller cycle, the motor controller independently
interpolates the data values between two specified position values, as shown in the following diagram.
Position
t
1
2
1
Synchronisation interval
2
Position control interval
Fig. 7.7
Positioning task linear interpolation between two data values
In the following, the objects needed for the interpolated position mode are described first. A sub
sequent functional description comprehensively covers the activation and sequencing of parameter
setting.
7.4.2
Description of the Objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
60C0
h
VAR
interpolation_submode_select
INT16
rw
60C1
h
REC
interpolation_data_record
rw
60C2
h
REC
interpolation_time_period
rw
60C3
h
ARRAY
interpolation_sync_definition
UINT8
rw
60C4
h
REC
interpolation_data_configuration
rw