![Festo CMMP-AS-***-M0 Series Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/festo/cmmp-as-m0-series/cmmp-as-m0-series_manual_2283119145.webp)
5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
145
Object 6510
h
_B0
h
: cycletime_current_controller
Through the object cycletime_current_controller, the cycle time of the current regulator in micro
seconds can be read.
Sub-Index
B0
h
Description
cycletime_current_controller
Data Type
UINT32
Access
ro
PDO mapping
no
Units
μs
Value Range
–
Default Value
0000007D
h
Object 6510
h
_B1
h
: cycletime_velocity_controller
Through the object cycletime_velocity_controller, the cycle time of the speed regulator in micro
seconds can be read.
Sub-Index
B1
h
Description
cycletime_velocity_controller
Data Type
UINT32
Access
ro
PDO mapping
no
Units
μs
Value Range
–
Default Value
000000FA
h
Object 6510
h
_B2
h
: cycletime_position_controller
Through the object cycletime_position_controller, the cycle time of the position regulator in micro
seconds can be read.
Sub-Index
B2
h
Description
cycletime_position_controller
Data Type
UINT32
Access
ro
PDO mapping
no
Units
μs
Value Range
–
Default Value
000001F4
h