5
Setting parameters
126
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
Index
202F
h
Name
synchronisation_selector_data
Object Code
RECORD
No. of Elements
1
Sub-Index
07
h
Description
synchronisation_main
Data Type
UINT16
Access
rw
PDO mapping
no
Units
–
Value Range
Table
Default Value
–
Bit
Value
Meaning
0
0001
h
0: Synchronisation inactive
1: Synchronisation active
1
0002
h
“Flying saw” not possible
8
0100
h
0: Synchronisation during homing
1: No synchronisation during homing
Object 2023
h
: synchronisation_filter_time
Through the object synchronisation_filter_time, the filter time constant of a PT1 filter is established,
with which the synchronisation speed is smoothed. This can be necessary especially with a low number
of lines, since even small changes in the input value here can correspond to high speeds. On the other
hand, the drive might no longer be in a position to follow a dynamic input signal quickly enough if filter
times are high.
Index
2023
h
Name
synchronisation_filter_time
Object Code
VAR
Data Type
UINT32
Access
rw
PDO mapping
no
Units
μs
Value Range
10 … 50000
Default Value
600