5
Setting parameters
Festo – GDCP-CMMP-M3/-M0-C-CO-EN – 1510b – English
101
Object 6410
h
_14
h
: motor_temperature_sensor_polarity
This object is used to determine whether a normally closed contact or a normally open contact is used
as a digital motor temperature sensor.
Sub-Index
14
h
Description
motor_temperature_sensor_polarity
Data Type
INT16
Access
rw
PDO mapping
yes
Units
–
Value Range
0, 1
Default Value
0
Value
Meaning
0
N/C contact
1
N/O contact
Object 6510
h
_2E
h
: motor_temperature
With this object, the current motor temperature can be read if an analogue temperature sensor is con
nected. Otherwise, the object is undefined.
Index
6510
h
Name
drive_data
Object Code
RECORD
No. of Elements
51
Sub-Index
2E
h
Description
motor_temperature
Data Type
INT16
Access
ro
PDO mapping
yes
Units
°C
Value Range
–
Default Value
–
Object 6510
h
_2F
h
: max_motor_temperature
If the motor temperature defined in this object is exceeded, a reaction takes place in accordance with
error management (error 03-0, over-temperature motor analogue). If a reaction that stops the drive is
parametrised, an emergency message is sent.
For parametrisation of error management