8. Startup
86
Festo P.BE-CMMP-AS-3A-HW-EN 0708NH
8.
Startup
8.1
General connection instructions
As the routing of the connecting cables is critical for EMC, it is es-
sential that you read Chapter 7.13.5 EMC-compliant wiring
(Page 84)!
Warning
DANGER!
Failure to follow the instructions in Chapter 2 Safety instructions for
electric drives and controllers (Page 12) can result in material dam-
age, injury, electric shock, or in extreme cases, even to fatalities.
8.2
Tools / material
Tool
-
Screwdriver size 1
-
Serial interface cable
-
Encoder cable
-
Motor cable
-
Power supply cable
-
Controller enable cable
8.3
Connecting the motor
Connecting the
motor
1.
Insert the motor cable plug in the corresponding socket on the
motor and secure it.
2.
Insert the PHOENIX plug into the socket [X6] on the device.
3.
Clamp the cable shields to the shield terminals (not suitable as
strain-relief)
4.
Insert the motor cable plug in the corresponding socket on the
motor and secure it.
5.
Insert the D-SUB plug into socket [X2A] resolver or [X2B] en-
coder of the device and secure the locking screws.
6.
Check all plug connectors once again.