B Reference
paramete
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
97
B.4.2
Device data – version numbers
PNU 100
Hardware version of the manufacturer (Manufacturer Hardware Version)
Subindex 1
Class: Array
Data type: uint16
FW …
Access: ro
Reading the hardware version. Coding of the hardware version number contains the revision numbers
(creation date) of the plugged-in printed circuit boards.
Creation date format (2nd byte/1st byte)
Byte
Significance
1 (LSB)
Year
2 (MSB)
Month
Tab. B.9
PNU 100
PNU 101
Firmware version of the manufacturer (Manufacturer Firmware Version)
Subindex 1 … 4
Class: Array
Data type: uint16
FW …
Access: ro
Reading of the firmware version. Coding of the firmware version number of the device consists of the
4 numerals (e.g. “1.2.3.4”) of the subindexes.
Subindex 1
Main version number (Major Version Number)
1st numeral of the firmware version
Subindex 2
Secondary version number (Minor Version Number)
2nd numeral of the firmware version
Subindex 3
Revision number (Revision Number)
3rd numeral of the firmware version
Subindex 4
Build number (Build Number)
4th numeral of the firmware version
Tab. B.10
PNU 101
PNU 102
FHPP version (Version FHPP)
Subindex 1
Class: Var
Data type: uint16
FW …
Access: ro
Reading of the FHPP version. The FHPP version number of the device consists of 4 numerals (e.g. “xxyy”).
Format (16 bit, BCD)
Numerals
Significance
xx
Main version number
yy
Secondary version number
Tab. B.11
PNU 102