![Festo CMMO-ST-C5-1-LKP Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/festo/cmmo-st-c5-1-lkp/cmmo-st-c5-1-lkp_original-instructions-manual_2283105095.webp)
B Reference
paramete
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
95
Temperature data
è
Current temperature CPU
(Actual Temperature CPU)
1063
1
int8
Min./max. temperature CPU
(Min./Max. Temperature CPU)
1065
1, 2
int8
Current temperature output stage
(Actual Temperature Output Stage)
1066
1
int8
Min./max. temperature output stage
(Min./Max. Temperature Output Stage)
1068
1, 2
int8
General drive data
è
Tool load/basic mass load
(Tool Load/Ground Mass)
1071
1
uint32
Current intermediate circuit voltage
(Actual Intermediate Circuit Voltage)
1073
1
uint32
Current control section voltage
(Actual Control Section Voltage)
1074
1
uint32
Current string currents
(Actual Phase Current)
1075
1 … 3
int32
Torque pilot control
(Torque Feed Forward Control)
1080
1
uint16
Tab. B.8
Axis parameters: electric drives 1