B Reference
paramete
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
137
B.4.19
Factor group
PNU 600
Position powers of ten exponent (Position Notation Index)
Subindex 1
Class: Var
Data type: int8
FW …
Access: rw2
Reading or parameterisation of the powers of 10 exponent with the1 SINC converted to 1 basic unit
value.
Example:
Power of 10 exponent = -7
Basic unit (0x01) = metre
Calculation:
– 1 SINC: 1 * 10
-7
m = 0.1 μm
– 10,000 SINC: 10,000 * 10
-7
m = 1 mm
Tab. B.120 PNU 600
PNU 601
Position unit of measurement (Position Dimension Index)
Subindex 1
Class: Var
Data type: uint8
FW …
Access: rw2
Reading or parameterisation of the system of measurement in relation to the basic unit.
Value
Significance
0x00 (0)
Undefined/user specific
0x01 (1)
Metre (SI unit)
0x41 (65)
Degree
0xF0 (240)
Inch
0xF6 (246)
Revolutions
Tab. B.121 PNU 601