5
Commissioning
Festo – GDCP-CMMO-ST-EA-SY-EN – 2017-05c – English
121
5.7.4
Integration in a network
Note
Unauthorised access to the device can cause damage or malfunctions. When connect
ing the device to a network:
Protect your network from unauthorised access.
Measures for protecting the network include:
– Firewall
– intrusion prevention system (IPS)
– Network segmentation
– Virtual LAN (VLAN)
– Virtual Private Network (VPN)
– Security at a physical access level (Port Security).
For further information, please refer to the guidelines and standards for security in in
formation technology, e.g. IEC 62443, ISO/IEC 27001.
Prior to integration in a network, the IP addressing of the device must be changed with
FCT. The IP configuration on the device can be changed without the current IP configura
tion of the device matching that of the PC.
DHCP/IPv4 Addressing
Description
Client
Automatic
The device obtains its IP configuration from a DHCP server in your
network. This method is necessary for network operation if another
DHCP server already exists on the network.
static
The IP configuration of the device can be permanently assigned manually.
However, the device can only be addressed if the assigned IP configura
tion matches the IP configuration of the PC. Permanently set IP configura
tions do not become effective until after a reboot (Power OFF, ON).
Tab. 5.15 TCP/IPv4 setting for integration in a network