BLUEHELIX TECH RRT H
170
EN
cod. 3541C673 - Rev. 00 - 11/2020
Use of Ø50 and Ø60 flexible pipe (for ducting only)
The chart includes the starting accessories code 041087X0 for Ø50 and code 041050X0 for Ø60.
Up to 4 m. of Ø80 mm flue can be used between the boiler and the passage with reduced width (Ø50 or Ø60), and up
to 4 m. of Ø80 mm flue on the intake (with max. length of Ø50 and Ø60 flues).
To use this width, follow the instructions below.
Access the
SC
menu (follow the instructions given in par. “"Sc" - Combustion Control Parameters Menu” on page 179)
and bring the parameter
SC04
to a value corresponding to the length of the flue used.
fig. 27- Chart for flue parameter choice
fig. 26
A =
Ø50 - 17 m MAX
Ø60 - 45 m MAX
max 4 m
Ø80
max 4 m
Ø80
A
m
SC04
0
10
20
30
40
50
12
10
8
6
4
2
0
13
FLEX
Ø
50
FLEX Ø60