Storage and transport/Electrical connection

XI. Storage and transport

Store the equipment and accessories out of children’s reach in a dark and dry place at above 
freezing temperature. The ideal storage temperature is between 
5 and 30 °C. Store the electric tool in its original packaging.

m

 

ATTENTION! The appliance must unconditionally be secured against falling or turning 

down during transport.
The machine must only be lifted and transported on its frame or the frame plate.

m

 

CAUTION! Two person handling required. Weight is 16.5 kg.

XII. Electrical connection

The electrical motor installed is connected and ready for operation. The connection complies 
with the applicable European standards. The customer‘s mains connection as well as the ex-
tension cable used must also comply with these regulations.

m

 

ATTENTION! The power supply cord of this machine has an equipment-grounding con-

ductor and a grounding plug. The plug must be plugged into an appropriate outlet which 
is properly installed and grounded in accordance with all local codes and ordinances.

m

 

WARNING! Check the voltage! The voltage must comply with the information on the 

rating label!

The customer‘s mains connection as well as the extension cable used must also comply 
with these regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often damaged.
This may have the following causes:
•  Passage points, where connection cables are passed through windows or doors.
•  Kinks where the connection cable has been improperly fastened or routed.
•  Places where the connection cables have been cut due to being driven over.
•  Insulation damage due to being ripped out of the wall outlet.
•  Cracks due to the insulation ageing.
Such damaged electrical connection cables must not be used and are life-threatening due to the 
insulation damage.Check the electrical connection cables for damage regularly. Make sure that 
the power is switched off before inspecting the cable. Electrical connection cables must comply 
with the applicable European standards and must be correctly marked. Only use connection 
cables with the marking ''H05VV-F''.Replacement cables can only be fitted by an approved and 
certified electritian. If you are in any doubt please contact the help line at the foot of this page.

Содержание BDG 915

Страница 1: ...the problem as quickly as possible once it has been brought to our attention In the unlikely event of such an occurrence or if you require any information about the product please contact us via our h...

Страница 2: ...15 16 2 1 14 3 19 5 6 4 9 6 20 11 17 Package contents part list 1 Belt Disc sander 2 Locking screw for grinding sanding table 3 Grinding belt pre assembled 4 Stop rail 5 Grinding sanding disk 6 Cross...

Страница 3: ...7 0 15 45 max 1 6 mm 3 14 7 15 6 14 13 16 7 W 17 W R 18 W 19 1 14 20 12 15 16 13...

Страница 4: ...8...

Страница 5: ...ctions may cause danger to life or danger of serious injuries Warning In case of non compliance danger to life risk of injury or damage to the tool possible Read the operating instructions to reduce t...

Страница 6: ...ons are intended to make it easier for you to get familiar with your device and utilise its intended possibilities of use The operating instructions contain important notes on how to work safely prope...

Страница 7: ...livery Open the packaging and remove the device carefully Remove the packaging material as well as the packaging and transport bracing if availa ble Check that the delivery is complete Check the devic...

Страница 8: ...uipment has not been designed for use in commercial trade or indus trial applications Our warranty will be voided if the equipment is used in commercial trade or industrial businesses or for equivalen...

Страница 9: ...al injury b Use personal protective equipment Always wear eye protection Protective equipment such as a dust mask non skid safety shoes hard hat or hearing protection used for appro priate conditions...

Страница 10: ...g Use the power tool accessories and tool bits etc in accordance with these instructions taking into account the working conditions and the work to be performed Use of the power tool for operations di...

Страница 11: ...ionswhereasuddenslipcouldcauseyourhandtotouchthesandingbelt ordisc When sanding a large piece of material provide an additional support at table height Never sand an unsupported workpiece Secure the w...

Страница 12: ...ARNING Always pull the power plug before making adjustments to the equipment All covers and safety devices have to be properly fitted before the equipment is switched on It must be possible for the gr...

Страница 13: ...position In this position you can use the grinding sanding table to support the workpiece To do this first loosen the two allen screws 17 and then remove the stop rail 7 The grinding table can now be...

Страница 14: ...bolts are used make sure bolts are long enough to go through holes in belt disc sander the material being mounted to and the lock washers and hex nuts On Off switch 12 The grinder sander can be switc...

Страница 15: ...senthetwoAllenscrews 17 andthenremovethestoprail 7 Thegrindingtablecannowbe pushedintotheholeintheholdertube 20 andfixedwiththescrew 1 Note Sand long workpieces with the sanding belt in the vertical p...

Страница 16: ...iatelyeachtimeyouhavefinishedusingit Clean the equipment regularly with a moist cloth and some soft soap Do not use cleaning agents or solvents these could attack the plastic parts of the equipment En...

Страница 17: ...which are in perfect working order Service and clean the appliance regularly Adapt your working style to suit the appliance Do not overload the appliance Have the appliance serviced whenever necessary...

Страница 18: ...cal codes and ordinances m WARNING Check the voltage The voltage must comply with the information on the rating label The customer s mains connection as well as the extension cable used must also comp...

Страница 19: ...sed of with household waste This symbol indicates that this product must not be disposed of together with domes tic waste in compliance with the Directive 2012 19 EU pertaining to waste electrical and...

Страница 20: ...service centre Every attempt to carry out a re pair can be dangerous if it is not done by skilled personnel Machine gets slower during work Too much pressure put on the workpiece Reduce the pressure...

Страница 21: ...25...

Страница 22: ...Juni 2011 zur Beschr nkung der Verwendung bestimmter gef hrlicher Stoffe in Elektro und Elektronikger ten The object of the declaration described above fulfils the regulations of the directive 2011 65...

Отзывы: