FORCE W
235
EN
cod. 3541V232 - Rev 00 - 08/2021
- Parameters
Each system requires a different parameterization. Follow the access procedure given below.
“Configuration - Parameters Menu”
Check/Change parameter
b02
of the “Transparent Parameters Menu” to
8
.
Check/Change parameter
b08
of the “Transparent Parameters Menu” to
1
.
Check/Change parameter
b04, b05 and b06
of the "Transparent Parameter Menu" according to the values given in the
table ”Configuration - Parameters Menu” on page 256 .
- Optional features
In addition to the electrical connections of the previous figure (necessary for this system configuration) there are options
that do not require settings.
fig. 47
Legend
139
Remote control: it can be installed instead of 72
to manage the request of the 1st zone (direct)
301
Fault indication (voltage-free contact output): the
example shows the connection of a 230Vac
lamp
302
Remote reset input (230Vac): the example
shows the connection of a double-pole switch at
230Vac, allowing the resetting of a block type
fault
357
Fault indication (230Vac): the example shows
the connection of a 230Vac lamp
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
37 38 39 40 41 42 43 44
FUSE
3.15A
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18
L
N
301
302
139
357
L N