FVI-7004 KIT & FVI-7008 KIT 

2 WIRE INTERCOM SYSTEM

Please read this manual carefully before using the product you purchase, and keep it well for future use.We reserve the right to 
modify the specification in this manual at any time without notice. 

FVI-7013

FVI-7014

FVI-7018

RF CARD

RF CARD

Quick Guide

Содержание FVI-7004 KIT

Страница 1: ...M Please read this manual carefully before using the product you purchase and keep it well for future use We reserve the right to modify the specification in this manual at any time without notice FVI 7013 FVI 7014 FVI 7018 RF CARD RF CARD Quick Guide ...

Страница 2: ...r FVI 6011DBC4A 1 Power Supply FVI 6017PC6 1 Power cable 4 Proximity Cards 2 Management Cards Add Card Delete Card FVI 7008 KIT consists of 1 Outdoor Station FVI 7018 1 Surface Box FVI 7000 8 Indoor Unit FVI 7013 2 4 Branch Controller FVI 6011DBC4A 1 Power Supply FVI 6017PC6 1 Power cable 8 Proximity Cards 2 Management Cards Add Card Delete Card ...

Страница 3: ... BUS 1 Indoor Monitor 2 3 4 5 6 EXTEND SW SW EXT RING GND BUS 1 Indoor Monitor 2 3 4 5 6 EXTEND SW SW EXT RING GND BUS 1 Indoor Monitor 2 3 4 5 6 EXTEND SW SW EXT RING GND BUS 1 Indoor Monitor 2 3 4 5 6 EXTEND SW SW EXT RING GND FVI 6017PC6 RoomCode 01 M S Master 0 RoomCode 02 M S Master 0 RoomCode 03 M S Master 0 RoomCode 04 M S Master 0 WorkMode 0 DS Code 0 RF CARD RF CARD FVI 7014 FVI 7013 FVI ...

Страница 4: ... SW EXT RING GND FVI 6017PC6 RoomCode 01 M S Master 0 RoomCode 02 M S Master 0 RoomCode 03 M S Master 0 RoomCode 04 M S Master 0 WorkMode 0 DS Code 0 SW DBC4A 4A BUS BUS 1 2 3 4 OUT ON OFF BUS 1 Indoor Monitor 2 3 4 5 6 EXTEND SW SW EXT RING GND BUS 1 Indoor Monitor 2 3 4 5 6 EXTEND SW SW EXT RING GND BUS 1 Indoor Monitor 2 3 4 5 6 EXTEND SW SW EXT RING GND BUS 1 Indoor Monitor 2 3 4 5 6 EXTEND SW...

Страница 5: ...m you want Down Decrease button Press to decrease the value Up Increase button Press to increase the value Speaker Send out vioce from the visitor Talk Mon button Press to communicate hands free with visitor Press to view the outdoor condition in standby mode Unlock button Press to release the door Call button Unlock 2nd button In standby mode pick up handset then press Call button to activate the...

Страница 6: ... NO Normally open contact of the relay EB Exit button positive connection port EB Exit button negative connection port JP LK For electronic lock safety type setting refer to door lock connections SET DIP switches for system configurations CN KMB Call button module connection port CN T COIL Reserved CN FUN Touch sensor keypad module or TFT display module connection port CN WGN Card reader module co...

Страница 7: ...e select 1 2 3 4 5 6 ON Default setting set OFF when using the default codes of the button 1 2 3 4 5 6 ON Set ON when using the programmed codes of the button Bit 5 unlock time quick setting 1 2 3 4 5 6 ON Default setting unlocking time 5 seconds 1 2 3 4 5 6 ON Unlocking time 10 seconds can be changed by door station or software Bit 6 cryptic key setting 1 2 3 4 5 6 ON Default setting normally key...

Страница 8: ...ton to select next digital How to enter the installation setting page 00 00 00 01 00 AUTO Exit 0000 Exit Next When you want to set the monitor parameter you must to know the setting code How to know the machine code Press button on this page 0000 Exit Next Use button to search the code you want 2412 Initial 3006 3600 Monitor Time Set 8000 8003 Local Addrees Exit Last Next ...

Страница 9: ...1 2 3 4 5 6 ON Code 18 1 2 3 4 5 6 ON Code 29 1 2 3 4 5 6 ON Code 8 1 2 3 4 5 6 ON Code 19 1 2 3 4 5 6 ON Code 30 1 2 3 4 5 6 ON Code 9 1 2 3 4 5 6 ON Code 20 1 2 3 4 5 6 ON Code 31 1 2 3 4 5 6 ON Code 10 1 2 3 4 5 6 ON Code 21 1 2 3 4 5 6 ON Code 32 1 2 3 4 5 6 ON Code 11 1 2 3 4 5 6 ON Code 22 Bit 6 line terminal setting Bit state Setting Bit state Setting 1 2 3 4 5 6 ON Monitor not at the end o...

Страница 10: ...s DIP3 switch set to off 1 2 3 4 5 6 ON RF CARD 01 02 03 04 DIP3 switch set to on 1 2 3 4 5 6 ON 7 Call codes The door station automatically assigns the call codes to the connected module s buttons Regardless of the structure of the call button module the button numbers are listed from the top to bottom and from left to right in the case of double row buttons ...

Страница 11: ... Door Release Operation 1 Press CALL button on outdoor station the Monitor rings at the same time the screen displays the visitors image 2 Press TALK MON Button on monitor you can communicate hands free with the visitor for 90 seconds After finishing communication press TALK MON button again to end the communication If nobody answers the phone the screen will be turned off automatically after 40 s...

Страница 12: ...Unlock type 12V 300mA Jumper position in 1 2 12V LK LK N O EB EB JP_LK 1 2 3 Exit button Power off to Unlock type Power off to Unlock type 12V LK GND LK COM N O EB EB Take off the Jumper JP_LK Cut off the line 1 2 3 Exit button 12V LK GND LK COM N O EB EB Take off the Jumper JP_LK Cut off the line 1 2 3 Exit button Power supply 26Vdc Power Consumption Of Outdoor Station 1W in standby 5W in working...