background image

6

EN

d)  

Under abusive conditions, liquid may be 
ejected from the battery; avoid contact.If 
contact accidentally occurs, flush with water. 
If liquid contacts eyes, additionally seek 
medical help

Liquid ejected from the battery 

may cause irritation or burns.

Service:

a)  

Have your power tool serviced by a 
qualified repair person using only identical 
replacement parts.

 

This will ensure that the 

safety of the power tool is maintained.

For the charger:
Intended use

Charge only CDA1106 20V max. 2.0 Ah Li-ion 
type rechargeable battery packs. Other types of 
batteries may burst causing personal injury and 
damage.
a)  

The appliance is not to be used by persons 
(including children) with reduced physical, 
sensory or mental capabilities, or lack of 
experience and knowledge, unless they have 
been given supervision or instruction 

b)  

Children being supervised not to play with 
the appliance

c)   Do not recharging non-rechargeable batteries!
d)   During charging, batteries must be placed in the 

well ventilated area!

Residual risks:

Even when the power tool is used as prescribed it 
is not possible to eliminate all residual risk factors. 
The following hazards may arise in connection with 
the power tool’s construction and design:
a)  

Health defects resulting from vibration emission 
if the power tool is being used over longer 
period of time or not adequately managed and 
properly maintained.

b)  Injuries and damage to property to due to 

broken accessories that are suddenly dashed.

 

Warning!

 This power tool produces an 

electromagnetic field during operation. 
This field may under some circumstances 
interfere with active or passive medical 
implants. To reduce the risk of serious or 
fatal injury, we recommend persons with 
medical implants to consult their physician 
and the medical implant manufacturer 
before operating this power tool.

Electrical safety

When using electric machines always observe the 
safety regulations applicable in your country to 
reduce the risk of fire, electric shock and personal 
injury. Read the following safety instructions and 
also the enclosed safety instructions.

Always check that the voltage of the 
power supply corresponds to the voltage 
on the rating plate label.

Class II machine - Double insulation - 
You don’t need any earthed plug.

2.  MACHINE INFORMATION

Technical specifications

Battery CDA1106

Charger  

CDA1107

Input of charger 

220-240V~ 50/60Hz 1.2A

Output of charger 

21V DC, 2.2A

Battery charging time 

60 min

No load speed 

13.000 rpm

Max. blower velocity 

180 km/h

Max air volume 

5 m³/min

Weight (incl. battery) 

1.9 kg

Sound pressure level LPA 

76.3 dB(A) K=3 dB(A)

Sound power level LWA 

84.7 dB(A) K=3 dB(A)

Vibration value 

1.370 m/s

2

 K=1.5 m/s

2

Vibration level

The vibration emission level stated in this 
instruction manual has been measured in 
accordance with a standardized test given in 
EN60745; it may be used to compare one tool 
with another and as a preliminary assessment of 
exposure to vibration when using the tool for the 
applications mentioned.

•   Using the tool for different applications, or with 

different or poorly maintained accessories, 
may significantly increase the exposure level.

•   The times when the tool is switched off or 

when it is running but not actually doing the 
job, may significantly reduce the exposure 
level.

Protect yourself against the effects of vibration by 
maintaining the tool and its accessories, keeping 
your hands warm, and organizing your work 
patterns.

Содержание LBM1010

Страница 1: ...WWW FERM COM EN Original instructions 04 LBM1010...

Страница 2: ...2 Fig B Fig A 8 7 6 8 7 1...

Страница 3: ...3 Fig C1 Fig C3 Fig C2 3 1 4 2 1 5 1...

Страница 4: ...injury loss of life or damage to the tool in case of non observance of the instructions in this manual Risk of electric shock Wear hearing protection Wear eye protection Wear dusk mask Danger Keep ha...

Страница 5: ...the cable Disconnect the appliance from the mains supply Before clearing a blockage Before checking cleaning or maintaining the appliance If the appliance starts to vibrate abnormally Whenever you lea...

Страница 6: ...r passive medical implants To reduce the risk of serious or fatal injury we recommend persons with medical implants to consult their physician and the medical implant manufacturer before operating thi...

Страница 7: ...lly pushed into the slot Plug the charger 4 in an electrical outlet and wait a while The LED indicator 5 on the charger 4 will lighten up and show the charging status Charging indication light Fig C2...

Страница 8: ...onents ENVIRONMENT Faulty and or discarded electrical or electronic apparatus have to be collected at the appropriate recycling locations Only for EC countries Do not dispose of power tools into domes...

Страница 9: ...R det af 8 juni 2011 om begr nsning af anvendelsen af visse farlige stoffer i elektrisk og elektronisk udstyr HU Felel ss g nk teljes tudat ban kijelentj k hogy ez a term k teljes m rt kben megfelel...

Страница 10: ...10 Spare parts list LBM1010 Article No Description Position No 410832 Switch 15 CDA1106 Li Ion Battery 20V 2 0Ah CDA1107 Fast charger...

Страница 11: ...11 Exploded view...

Страница 12: ...WWW FERM COM 2017 FERM B V 1712 19...

Отзывы: