Table 4. Ordering Information
Part Number
Model
Description
Detector Heads - Ionization Smoke
70-540000-001
CPD-7054
Ionization Advanced Smoke Detector
(cULus)
70-540000-002
CPD-7054D
Ionization Advanced Smoke Detector
(cULus)
Detector Heads - Photoelectric Smoke
71-570000-001
PSD-7157
Photoelectric Advanced Smoke Detector
(cULus)
71-570000-002
PSD-7157D
Photoelectric Advanced Smoke Detector
(cULus)
Detector Heads - Heat
70-520000-001
THD-7052
135
o
F Fixed Heat Detector, 15
o
F Rate of Rise
(cULus)
70-530000-001
THD-7053
135
o
F Fixed Heat Detector
(cULus)
Detector Bases
70-501000-001
2-WIRE
2-Wire Standard Base
70-501000-002
2WRLT
2-Wire Base with Remote LED & Test Capabilities
70-501000-005
2WRB
2-Wire Base with Auxiliary Relay, Remote LED & Test Capabilities
70-501000-101
4WRB
4-Wire Base with Auxiliary Relay, Remote LED & Test Capabilities
70-500000-004
2WRM
Spare 2-Wire Relay Module
70-500000-102
4WRM
Spare 4-Wire Relay Module
Detector Accessories
06-117883-001
Test Magnet
29-116788-001
EOL Supervisory Relay
70-200000-911
RA-911
Remote Alarm Indicator
70-200000-914
RA-914
Remote Alarm Indicator with Smoke Detector Test Switch
70-500000-003
DST-003
Advanced Handheld Wireless Smoke Detector Sensitivity Tester
70-501000-003
MA-001
Mechanical Retrofit Adapter
Table 3. Detector Base Options
Part Number
Model
CID
Description
70-501000-001
2-WIRE
FE51A
2-W Base. Connects to circuit via screw terminals
70-501000-002
2WRLT
FE52A
2-W Base w/ Remote LED & Test capabilities. Connects to detection via screw
terminals. Minimum Alarm Current 15 mA @ 24 VDC.
70-501000-005
2WRB
FE55A
2-W Base w/ 2WRM, Remote LED & Test capabilities. Connects to detection circuit
via pigtail leads. Minimum Alarm Current 19 mA @ 24VDC
70-501000-101
4WRB
N/A
4-W Base w/ 4WRM, Remote LED & Test capabilities. Connects to detection circuit
via pigtail leads. Minimum Alarm Current 35 mA @ 24VDC
70-500000-004
2WRM
N/A
SPDT Relay for 2WRB Bases. Contacts rated 1.0 A, 30 VDC/ 0.5 A, 125 VAC
70-500000-102
4WRM
N/A
SPDT Relay for 4WRB Bases. Contacts rated 1.0 A, 30 VDC / 0.5 A, 125 VAC
70-501000-003
MA-001
MAFE1
Mechanical Adapter allows CPD-705X & PSD-715X Detectors to physically connect to
Base P/Ns 70-201000-001, -002, -003, -005 & DH-22