OPERATING INSTRUCTIONS

This storage heater  takes in Energy

when electricity tariffs are low and

dissipates it when tariffs are normal.

OPERATION

SAFETY INSTRUCTIONS

1. Ventilate rooms well during commissioning

2. Do not move the heater in any way once installed

without the services of a competent electrician.

3. Do not cover the heater with clothing etc. at any time

or position furniture close to or against the heater.

4. Ensure a clearance of at least 150mm between heaters

and curtains.

5. Floor standing heaters must only be fitted with the

back against a wall.

6. Should your heater fail to operate either employ the

services of a competent electrician

ALSO REFER TO COVER PAGE

COMMISSIONING

Set both the Input Control and the Output Control to 6

and leave the heater for 48 hours.

Following the commissioning period adjust the

controls as stated below.

CONTROL FUNCTIONS

THE INPUT CONTROL

SETTING THE CONTROLS

The controls are located under the hinged flap at the top right
hand corner of the heater.
To adjust the controls on the heater use a coin and engage it
in the clots provided on the top surface of the knob.  There
are no user adjustable controls on the WMX706.

CLEANING

To maintain the appearance of the heater wipe occasionally

with a  dry cloth when the heater is cool.

Do not use abrasive powders of furniture polish.

AFTER SALES SERVICE

Your Storage Heater is guaranteed for 

2

 year

s

 from date of

purchase.  We undertake to exchange or repair within the

period, any part found to be defective due to a manufacturing

fault.  This guarantee does not affect you statutory rights.

Should you require after sales service, please contact the

supplier through whom you purchased the heater

.

Please do not initially return faulty appliance, or part of an

appliance, to us as this may result in transit damage and/or a

delay in providing service.

Let us know your difficulty quoting the model number and

serial number (located along the wall bracket).  We will then

take the appropriate action.

THE OUTPUT CONTROL

For all models except WMX706N

Most of the stored heat is radiated from the casing during the
discharge period.  However, some of the heater is emitted
through the grille at the top of the heater and this additional
heat (or boost) is regulated by the Output Control.
With this set to 6 the boost begins in the early afternoon.
Turning the control towards 1 will progressively delay the
commencement of the boost.  At 3 the boost will start in the
evening.  Once set, the boost will repeat itself automatically
day after day.
If no boost is required e.g. when the room will be unoccupied
for a long period, set the Output Control to 1.  With the control
in this position, the heater will take less energy during the
next charging up period.

For models WMX712, 718, 724 only:

Initially set the input to 4.  If the heater does not maintain a
satisfactory room temperature the following day this setting
should be increased.  Conversely if the room temperature is
too high this setting should be reduced.
The input control should only require seasonal adjustments.