FENIX IMVICO
SM3000 OPERATION MANUAL
1) Connector model (user side):
6 positions, 6 contacts (RJ12 telephone jack)
2) Open drawer signal:
•
Output signal:
Output voltage: 24 V approx.
Output current: 1 A or less.
Warning:
In order to avoid over current and the SM3000 driver damage, the solenoid
resistance that opens the drawer must be > 24
Ω
. The maximum current consumption of
the SM3000 driver for the drawer opening is 1 A (maximum 0.512 sec).
•
Output wave form:
The
t1
(ON) and
t2
(OFF) times are specified by means of the
ESC p
command.
t1
x 2 ms
t2
x 2 ms
Fig. 2.7
- Output signal waveform for the drawer opening action.
13/55