FEMA ELECTRÓNICA . Series M . M60-P

14

1.12 To access the instrument

1.13 Modular system

Series M panel meters are designed to create a modular system. This 

modular system allows for addition, replacement or substitution of 

any of the internal modules conforming the instrument. Below is a 

graphic explanation for the position of each module.

To open the housing, use a flat screwdriver to free the fixation clips, 

if possible, in the following order : D, C, B and A. Remove the front 

cover. Let the inside of the instrument slide out of the housing.
To reinsert the instrument make sure that all modules are correctly 

connected to the pins on the display module. Place all the set into 

the housing, assuring that the modules correctly fit into the internal 

guiding slides of the housing. Once introduced, place again the front 

cover in front of the housing, placing first corner ‘X’ and then insert

-

ing clips ‘A’, ‘B’, ‘C’ and ‘D’ in this order.

X

A

C

B

D

Front Filter

Display Module

Optional Control Modules

Input Signal Module

Housing

Power Supply Module

Opt.3

Opt.2

Opt.1

Risk  of  electric  shock.  Removing  the  front  cover  will 

grant access to the internal circuits. Disconnect the in-

put signal to prevent electric shock to the operator. Op-

eration must be performed by qualified personnel only.

Observe precautions for handling ESD (electrostatic dis-

charge) sensitive devices

Содержание M60-P

Страница 1: ...fast access to alarm setpoints tare function on power up function measure function configurable reading brightness Universal AC and DC power Up to 3 optional modules for output and control relays tran...

Страница 2: ...m and minimum reading password protection 5 brightness levels Index 1 Panel meter M60 P 2 1 1 How to order 2 1 2 Front view 3 1 3 Rear view 3 1 4 Power connections 3 1 5 Signal connections 3 1 6 Mecha...

Страница 3: ...SQ Button LE Configuration menu see section 1 10 Fast access see section 1 10 6 1 6 Mechanical dimensions mm Signal see section 1 5 Jumpers see section 1 5 Option 1 Option 2 Option 3 Power see sectio...

Страница 4: ...5 W only meter 4 0 W meter with options Configuration 3 buttons front keypad and rear jumper 1 7 Technical specifications Ranges Accuracy Zin Max signal overload 4 20 mA 0 03 FS 11 Ohm 100 mA permanen...

Страница 5: ...E 3 inside the menus the LE 3 key functions as the ES CAPE key It leaves the selected menu and eventually will leave the whole menu When leaving the configuration menu with the LE 3 key the changed pa...

Страница 6: ...imum input signal The Field correction F cor functions allows to correct the instrument scaling parameters when the instrument is being installed on the field providing a fast and easy way to compensa...

Страница 7: ...ing of the alarm relays due to fluctuating input signals around the set point at Activation delay dEL 0 configure the delay to apply before alarm activation The activation delay starts counting when t...

Страница 8: ...ry of maximum MAX function displays the maximum reading value stored in memory It also provides a way to reset the value This parameter is eligible for configuration through the Fast access menu see s...

Страница 9: ...nt gives access to a list of functions configurable by the operator See section 1 8 for an ex planation on how to operate the fast access menu The Key UP Fast access K uP menu allows to select which f...

Страница 10: ...rE menu allows to operate the instrument for load cell and weight applications The tare function assigns the actual input signal value to a reading of 0 Kilos by adding an inter nal offset It does not...

Страница 11: ...access the configuration menu key SQ The fast access menu is not password pro tected 1 10 12 Function Password At the Brightness LIGh menu select the light intensity for the front leds With this funct...

Страница 12: ...0 to 100 Display Fixed digits Memory of maximum Memory of minimum Peak Hold Time seconds Alarm 2 menu Alarm 3 menu Relay inverted Locked alarm Alarms Alarm 1 Setpoint Hysteresis Active Alarm type Fiel...

Страница 13: ...f segments Value 2 to 31 Input 0 Display 0 Input 1 Display 1 On power up Delay Tare Seconds Option 1 Configuration menu for the module installed at Opt 1 Option 2 Configuration menu for the module ins...

Страница 14: ...that all modules are correctly connected to the pins on the display module Place all the set into the housing assuring that the modules correctly fit into the internal guiding slides of the housing O...

Страница 15: ...d off Brightness 3 strument must be assured Do not expose the instrument to excess of humidity Maintain clean by using a humid rag and do NOT use abrasive products such as alcohols solvents etc Genera...

Страница 16: ...tinuous Isolation 3500 Veff Type of terminal plug in screw terminal pitch 5 08 mm Slots allowed Opt 1 Opt 2 Opt 3 Terminal A Common Terminal B NO Normally open Terminal C NC Normally closed Power Opt...

Страница 17: ...pecial configuration Terminal A Vexc Terminal B Signal in mA or Vdc Terminal C GND Jumper M closed for mA Jumper V closed for Vdc For more information http fema es docs 4254_SERIES_M K S_ OPTIONS_manu...

Страница 18: ...Opt 2 Opt 1 Opt 3 B A G B A G Signal B A G Terminal B B signal from RS 485 bus Terminal A A signal from RS 485 bus Terminal G GND For more information http fema es docs 4254_SERIES_M K S_ OPTIONS_manu...

Страница 19: ...rograms Access to display values alarm status memory of maximum and minimum alarm setpoints Configuration from instrument front keypad through menu entries Opt 1 Opt 2 or Opt 3 depending on the positi...

Страница 20: ...out front key pad To configure the instrument remove the meter from the panel and remove the front filter Inter nal press buttons for configuration are accessible Optionally request the instrument pre...

Страница 21: ...1 THM benchtop housing Adapter96 x 96 mmfor96 x 48 mm instruments Adapter for DIN rail mount for Series M and Series K of panel meters Wall mount housing Together with the KIP protector offer a full...

Страница 22: ...FEMA ELECTR NICA Series M M60 P 22 Notes...

Страница 23: ...FEMA ELECTR NICA Series M M60 P 23 Notes...

Страница 24: ......

Отзывы: