INSTALLATION GUIDE

WILLO II RAIN SHOWER COLUMN BRUSHED NICKEL

W2RSCBN

1 x Single Spray

Handpiece

SYSTEM REQUIREMENTS

WHAT IS IN THE PACK

1 x Rain Head

1 x Rail & Arm

1 x Slider

Top Mounting B 

Chrome Flange

(Diverter Valve)

Bottom Mounting Bracket 

+ Chrome Flange

1 x Hose

2 x Screws

2 x Wall Anchors

To ensure the optimum performance and customer satisfaction please adhere to the following:

• Flush out all pipe work prior to installation.

• Maximum hot water temperature is 60˚C. If the water temperature exceeds 60˚C an approved tempering valve 

  must be fitted.

• Installation should comply with relevant local authority requirements.

• In accordance with good plumbing practice, filters should be fitted to supply lines to eliminate damage to the 

   ceramic cartridge from suspended solids.

• AS/NZS 3500.1 states that pressures above 500kPa can cause damage from water hammer, reduce the life of 

  appliances, taps & fittings, cause excessive noise in the system and recommend that a pressure limiting valve 

  (PLV) be fitted.

 MAXIMUM STATIC PRESSURE

Maximum static pressure 500kPa. If water 

pressure exceeds or is likely to exceed 

500kPa, an approved pressure limiting valve 

must be fitted.

Failure to comply with the above will void warranties.

 MINIMUM STATIC PRESSURE

Minimum static pressure 150kPa. To ensure 

optimal performance the static pressure must 

be greater or equal to 150kPa.