Extension cable.
If the use of an extension cord
is required, its length and con-
ductor cross-section must be adequate for the
application in order to prevent a voltage drop
in the extension cord, power loss and over-
heating of the power tool.
Otherwise, the
extension cable and power tool are prone to
electrical danger, and the working efficiency is
decreased.
Recommended dimensions of extension cords
at an operating voltage of 120 V – single-
phase a. c., with only BLS, BSS connected:
Intended use of the power tool:
BLS:
Hand-guided sheet metal shears for cut-
ting sheet metal in weather-protected envi-
ronments without water supply using the
application tools and accessories recom-
mended by FEIN.
BSS:
Hand-guided slitting shears for cutting
sheet metal and tight curves in weather-pro-
tected environments without water supply
using the application tools and accessories
recommended by FEIN.
Operation of the power tool off power generators.
This power tool is also suitable for use
with AC generators with sufficient power
output that correspond to the Standard
ISO 8528, design type G2. This Standard is
particularly not complied with when the so-
called distortion factor exceeds 10 %. When
in doubt, please refer to the generator
instruction/specification guide.
Operating the power tool off
power generators whose no-
load speed exceeds the voltage value on the
type plate of the power tool is prohibited.
Vibrations
Vibrational emission
value (nibbling)
–
m/s
2
–
ft/s
2
4.1
13.4
4.8
15.6
12.1
39.57
22.6
73.96
5.7
18.6
5.7
18.6
10.8
35.2
Measuring uncertainty
K
,
in
–
m/s
2
–
ft/s
2
1.5
4.9
1.5
4.9
1.5
4.9
1.5
4.9
1.5
4.9
1.5
4.9
1.5
4.9
REMARK: The sum of the measured emission value and respective measuring inaccuracy rep-
resents the upper limit of the values that can occur during measuring.
Wear hearing protection!
Measured values determined in accordance with the corresponding product standard.
Sound emission
BLS1.6E
BLS2.5E BLS3.5 BLS4.2
BSS1.6E BSS1.6CE
BSS2.0E
WARNING
Max. cable length, ft
Max. cable length, m
≤ 100
100
–200
200
–300
≤ 30
30
– 60
60
–100
Min. conductor size
A.W.G.
Min. conductorcross-
section, mm
2
16
14
12
1.5
2.5
4
WARNING