TST
Expanded Startup
WU
FEIG ELECTRONIC GmbH
Page 8 of 18
WU_erweiterte_ Inbetriebnahme4_GB.doc
7 Parameter
list
P.
[unit]
Range
Door Functions
Default
000
[Cycles]
Door cycle counter display
Display: 1234567
⇒
1234.
À
-key .567
Display: 67
⇒
67
005
[Cycles]
Displays number of door cycles until maintenance is required.
Display: 1234567
⇒
1234.
À
-key .567
Display: 67
⇒
67
010
[s]
0..200
Open hold time 1 (End position Upper - Eo)
0: Automatic closing deactivated
10
011
[s]
0..200
Open hold time 2 (Intermediate hold position - E1)
0 = turned off
10
025
[s]
0..20
Pre warning time / clearance time
0 = pre warning time deactivated
0
P.
[Einheit]
Stellbereich
Teaching in the end positions for electronic limit switches
ab
Werk
205
0..3
Selecting the positioning system:
0. Limit switch 1 (limit switch as normally closed, pre-limit switch normally
open)
1. Limit switch 2 (limit switch and pre-limit switch normally closed)
2. Incremental encoder (reference switch in lower end position)
3. DES (9600 baud)
0
210
0..5
Selecting the position calibrated by a deadman move (“teach in”):
0: no
→
None/Cancel
1: Eu
→
Lower and Upper limit switch (intermediate stop: see P244)
2: Eo
→
Upper limit switch (intermediate stop: see P244)
3: uo
→
Upper and Lower limit switch
4: E1
→
Intermediate stop limit switch (P244 is ignored)
5: al
→
(all) Lower, Upper and Intermediate Stop limit switch (per.
P244)
0
P.
[Unit]
Range
Correcting the end positions for electronic limit switches
Default
215
0..1
Request a new calculation of the limit switch bands
0: Do not correct
1: Request correction of limit switch bands
Parameter only active if automatic correction
Default
is set.
0
216
0..2
Automatic correction of limit switch bands
0: deactivated
1: deactivated
2: activated
0
221
[Inc]
±
125
Correction value for Lower end position
(set to 0 for new calibration !)
0
231
[Inc]
±
60
Correction value for Upper end position
(set to 0 for new calibration !)
0