5.14.
CFG16: Persistence Reset
The parameters in CFG16 are used to configure the Reader reset timing of the persistence flags of the Transponders.
The timing for reset of the persistence flags is used by the Reader in ISO Host Mode, Scan Mode , Buffered Read Mode
and Notification Mode.
Byte
0
1
2
3
4
5
6
Contents 0x00
0x00
PER-RESET-TIME
0x00
0x00
0x00
Default
0x0028
40 x 5ms = 200ms
Byte
7
8
9
10
11
12
13
Contents
0x00 0x00 0x00 0x00 0x00 0x00 0x00
Default
PER-RESET-TIME:
(Transpond-
er.PersistenceReset.Antenna.No1.PersistenceResetTime)
The timer value specifies a time which determines the reset of the Transponder select
state by a RF reset from the Reader. The timer PER-RESET-TIME starts after the Reader
gets a response from any Transponder. After this time has expired the Reader generates
a RF reset. The PER-RESET-Time has an effect only if the Reader does not use the
MUX. If a MUX is used the switching from one antenna to an other antenna resets the
Transponder state.
Timer ticks = 5ms
Maximum timer value = 5ms x 65534[0xFFFE] = 5,46125 min.