8.4. Operating elements
8.4.1. Operating/Programming Mode: Jumper J1
Jumper J1 is used to configure the operating and programming mode of the ID CPR.M02.
In standard operation the jumper is set to Position 1-2 (see Fig. 4.3.1-1). The reader is then in
normal operating mode.
If the jumper is set to Position 2-3, the integrated hardware bootloader starts after a reset. Since
the reader’s firmware however also has a software bootloader, the hardware bootloader option
should be used only if necessary.
For additional information about programming the reader, see the corresponding Application Note
„Firmware Update“.
Jumper position
Mode
1 - 2
Standard setting
:
The reader is in normal operating mode.
2 - 3
Activation of the hardware bootloader:
After a reset the reader’s CPU starts its hardware
bootloader, which can then be used for new pro-
gramming.
Table 3.4.1-1: Jumper J1
Fig. 3.4.1-1: Jumper J1
X1
J1
V2
V1
C315
X3
X4
Default
2
1
J1
3
C405