![Feig Electronic OBID Classic-Pro ID CPR.M02 Series Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/feig-electronic/obid-classic-pro-id-cpr-m02-series/obid-classic-pro-id-cpr-m02-series_installation-manual_3898669035.webp)
OBID
®
classic-pro
Installation
ID CPR.M02
FEIG ELECTRONIC GmbH
Page 35 of 42
M21001-3de-ID-B.doc
E N G L I S H
8.3. Display elements
The ID CPR.M02 Reader Module has a green LED (V1) and a red LED (V2) which are used as
display elements (Fig. 3.3-1).
Fig. 3.3-1: Position of LEDs V1 and V2
LED
Color
Standard setting
V1
Green
•
Flashes 4x after a reset.
•
Flashes continuously at a frequency of
2 Hz.
V2
Red
•
Flashes 4x after a reset.
•
Comes on for 1 second after successful
communication with a transponder.
Table 3.3-1: Standard setting for the LEDs
NOTE:
Up from Firmware-Version 1.08 the function of the red LED is connected to X1, Pin7 (CLS).
For current limitation an additional resistor with 470
Ω
is required.
X1
J1
V2
V1
X4
Содержание OBID Classic-Pro ID CPR.M02 Series
Страница 23: ......