IDENTIFICATION
ID MAX.U500i
6 Operating and Display Elements
Page 25 of 36
•
As long as the Teach-In Mode is active, the yellow LED (V4) is switched on. Access will be granted
immediately to all transponders which are read and stored in the reader during this time.
•
At first the new authorizations will be stored temporarily in the reader. If the Teach-In Mode is disabled
again by pressing the push button T1 briefly twice again, all new authorizations will be stored
permanently in the reader. These transponders will now have permanent access. Authorizations stored
permanently in the reader will still be available if the system was powered off, while temporarily stored
authorizations will be lost in the event of a power loss.
NOTE:
•
In case of power down during activated Teach-In Mode all temporarily stored authorizations are
lost and have to be read again.
•
In case of power down during deactivation of the Teach-In Mode (after pressing the push button
T1 twice within short time the second time) all authorizations stored in the reader may be lost.
A stable power supply must be ensured!
•
The use of the Teach-In Mode is only recommended for small systems with a manageable
number of authorized transponders and users.
•
It is possible to import access control data to the reader by connecting a USB flash drive.
•
Please note that in some vehicles RFID transponders may already be installed by the
manufacturer or other system provider. These transponders could also be detected by the reader
in Teach-In Mode.
6.2.2 Configuration Reset
By means of the push button T1 a complete configuration reset can be performed. Push the button for at
least 5 s until the reset LED below the button is switched on continuously. After releasing the push button the
reader performs a restart.
During a complete configuration reset all parameters of the reader will be reset back to factory default and
need to be configured again. Access authorizations stored in the access control reader are not affected.
6.3 Buzzer
The buzzer is located above the digital inputs on terminal X5. It is used to notify the service personnel of
events during maintenance and service.
6.4 Reader Power Adjustment
In order to achieve high reading ranges, it is necessary to set the reader output power to the highest allowed
level. This depends on the reader type used (EU/FCC) and the applicable radio regulations at the installation
site. The output power is adjustable in 100 mW steps from 0.1 W to 1 W.
NOTE:
•
Both in the EU version and in the FCC version of the reader the output power of the internal
antenna must not exceed 0.8 W.
•
The admissible max. output power is 2 W e.r.p. for EU versions and 4 W e.i.r.p. for FCC versions.
The output power depends on the antenna gain. For calculating the reader output power the
Excel file “Calc-RF-Power.xls” is available from FEIG ELECTRONIC GmbH. If a circular polarized
antenna is used the antenna gain [dBic] can be reduced by 3 dB. If using a linear polarized
antenna the max. antenna gain [dBi] must be used.
Содержание ID MAX.U500i Series
Страница 1: ...IDENTIFICATION M81211 2e ID B INSTALLATION ID MAX U500i EU 5118 001 00 FCC 5118 001 10...
Страница 9: ...IDENTIFICATION ID MAX U500i 4 Installation Page 9 of 36 Fig 2 Dimensional drawing side view...
Страница 10: ...IDENTIFICATION ID MAX U500i 4 Installation Page 10 of 36 Fig 3 Dimensional drawing top view opened housing...