![Feig Electronic ID ISC.MU02.02-CU Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/feig-electronic/id-isc-mu02-02-cu/id-isc-mu02-02-cu_manual_3882212081.webp)
OBID
i-scan
®
UHF
Manual
ID ISC.MU02.02
FEIG ELECTRONIC GmbH
Page 81 of 96
H90701-3e-ID-B
10.1.3. [0x24] Write Multiple Blocks
This command writes one or more data blocks.
REQUEST-DATA
4
5
1 Byte
UID_LNG
Bytes
1Byte
0x24
MODE
UID_LNG
UID
BANK
1 Byte
A_PW_LGT
Bytes
1 or 2 Bytes
( def. by
EXT_ADR)
1 Byte
1 Byte
DB-N times
DB-SIZE
Bytes
A_PW_LGT
A_PW
DB-ADR
DB-N
DB-SIZE
DB
Repeated DB-
N times
RESPONSE-DATA (STATUS = 0x03)
5
DB-ADR-E
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
EXT_ADR
UID_LF
ADR
ADR:
b000
non-addressed
b001
addressed
UID_LF:
If this bit is set the parameter UID_LNG must inserted into the protocol.
b0:
The protocol UID_LNG doesn't include the UID_LNG byte and
the UID field has a fixed length of 8 byte, from byte 6 to byte 13.
b1:
The protocol includes the parameter UID_LNG. The UID has a variable
length as defined in UID_LNG.
EXT_ADR:
If this bit is set the command includes extended address fields.
b0:
Transponder memory addressing is done by the 1 byte DB-ADR Field.
b1:
Transponder memory addressing is done by BANK and
2
byte DB-ADR
Field
UID_LNG:
Is a optional parameter and depends on the setting of UID_LF (see MODE). UID_LNG de-
fines the length of the following UID field.