8.1. ISO18000-3M3 Commands [0xB3]
This commands supports the functions of the ISO18000-3M3 Transponder
8.1.1. [0xB3] [0x18] Kill
This command writes one or more data blocks by using the Block write command of ISO18000-
3M3 Transponder.
REQUEST-DATA
6
7
1 Byte
EPC_LNG
Bytes
0x18
MODE
EPC_LF
EPC
1 Byte
K_PW_LNG
Bytes
1 Byte
K_PW_LNG
K_PW
RECOM
Bits
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
EPC_LF
RECOM
ADR
ADR:
b000
non-addressed
b001
addressed
EPC_LF:
If this bit is set the parameter EPC_LNG must inserted into the protocol.
b1:
The protocol includes the parameter EPC_LNG. The EPC has a variable
length as defined in EPC_LNG.
RECOM
b1:
If this bit is set the Recommissioning Bits will be inserted into the proto-
col.
EPC_LNG:
Is a optional parameter and depends on the setting of EPC_LF (see MODE). EPC_LNG
defines the length of the following EPC field.
EPC:
EPC