7.7. CFG8: Read Mode
– Miscellaneous Settings
The parameters of the CFG8 configuration block contain the special settings for the DM functionali-
ty. These are alarm sensitivity and the MISC register.
Byte
0
1
2
3
4
5
6
Contents
0x00
reserved
reserved
0x00
0x00
Default
0x0000
0x0000
Byte
7
8
9
10
11
12
13
Contents
reserved
reserved
reserved
reserved
reserved
MISC
SENSITIVITY
Default
00
00
00
00
00
00
00
MISC:
Special settings
Bit:
7
6
5
4
3
2
1
0
Function
-
-
-
-
reserved
CREATE BLACKLIST
CREATE BLACKLIST: (
OperatingMode.BufferedReadMode.Miscellaneous.Blacklist)
(
OperatingMode.NotificationMode.Miscellaneous.Blacklist)
Function
b 00
No Blacklist
b 01
-
b 11
Create Blacklist
For more information about the Blacklist and how to use it see document xxxx
SENSITIVITY:
(
OperatingMode.BufferedReadMode.Miscellaneous.DetectionSensitivity)
(
OperatingMode.NotificationMode.Miscellaneous.DetectionSensitivity)
Defines detectionsensitivity
Sensitivity
Function
0x00
Default
0x01
Minimal
0x02
Maximal
0xFF