5.4 CHANGING THE SAW BLADE
Protect yourself against cutting injuries by wearing gloves! Press the spindle locking button and turn the saw
blade until the spindle locking button stays pressed. The spindle lock may only be actuated when the saw
blade is stationary. Keep the spindle locking button pressed and loosen the Allen screw by turning the Allen
key anticlockwise. Pull back the saw guard. Now remove the Allen screw, the flange and the saw blade.
Before inserting the new blade, make sure that it is facing the right direction of rotation. This is indicated by
arrows both on the saw as well as the saw blade. They have to point in the same direction. After placing the
saw blade on the inner flange, make sure that the flat area of the outer flange (crowning to the outside)
re-engages in the spindle drive. Now hold the spindle locking button pressed and fix the Allen screw using
the Allen key.
5.5 WORKING WITH THE CIRCULAR HAND SAW
Only saw blades for cutting wood are suitable for your saw! Do not use any saw blades for cutting stone or
metal! Mark the desired cutting line with a pencil or similarly on the piece to be cut. To turn on the tool, press
the safety switch (12) and then press the on/off switch (13). To turn off the tool, release the on/off switch (13).
Always hold the saw firmly with both hands when working! Turn the tool on before applying it to the piece to
be cut. Lead the saw without applying additional pressure and allow the saw blade time to follow the cutting
line.
Attention: do not use any grinding wheels!
5.6 SWITCHING THE LASER ON AND OFF
•
Press the ON/OFF switch laser to switch it on;
•
Press the ON/OFF switch laser once more to switch it off;
NOTE:
if the batteries are spent, replace with the two 1.5V alkaline button cells (type L1154F).
6. MAINTENANCE AND CARE
6.1 OVERLOADING
Never apply excessive force when cutting. Too much pressure decreases the speed of the tool, while the
required power increases sharply. This leads to overloading, which can damage the motor. If the machine
becomes too hot, let it idle for two minutes and then let it rest. Clean the machine with a clean cloth and
brush. Do not use any solvents. Make sure the ventilation slots are not blocked!
6.2 DUST EXTRACTION
We recommend that you always attach an industrial vacuum cleaner when using the circular hand saw. In
the case of extensive woodworking, the power tool should be attached to suitable external dust extraction
equipment.
When using, always wear appropriately tested hearing protection!
Recommended nominal operating duration: a maximum of 20 minutes of continuous use. Quiet period after
continuous use: 5-10 minutes.
6.3 MALFUNCTIONING
If the circular saw does not function properly, we are providing you with several possible causes and the
corresponding solutions.
9