Burst
FY8300S can output waveform with specified number of cycles (called Burst)
from the CH1 channel. FY8300S supports control of burst output by CH2(internal),
manual or external trigger source; The signal generator can generate burst using
Sine wave, Square wave, Ramp wave, Pulse, Noise wave or arbitrary waveform
(except DC).
Enable Burst Function
Press the front panel
MOD
button, then press
MODE
button to enter burst
function. The instrument supports [CH2], [Ext. AC], [Ext. DC] and [manual] four
trigger output modes, which can be selected by the corresponding button. When
the burst function is enabled, press the
PARA
button to set the burst output
pulse number. Use arrow buttons and ADJ Knob to set the numbers from 1 to
1048575. Then the generator will output burst waveform according to current
configuration.
⚫
CH2 Trigger: CH1 will generate a burst when CH2 generates a pulse.
⚫
Ext. AC: CH1 will generate a burst when [Input] connector was inputted a
pulse.
⚫
Ext. DC: CH1 will generate a burst when [Trig IN] connector was inputted a
pulse.
⚫
MANU Trigger: User can trigger a burst by pressing ADJ Knob (OK button).
Press the [WAVE] button to change the current burst output signal waveform.
Press the [FREQ] button to change the current burst output signal frequency.
Press the [AMPL] button to change the current burst output signal amplitude.