Hydronic Towel Warmers
Installation and Operating Instructions
________________________________________________________________
11
1/2 inch
3/4 NPT
(Eccentric
Coupling
not used)
F lush
1/2 NPT
Coupling
or thread-to-sweat
adapter to be flush
with finished face
of wall.
PLUMBING PREPARATION
• If the eccentric coupling is used, a female 1/2
NPT coupling or thread-to-sweat adapter should
be flush with the finished face of the wall.
• If the eccentric coupling is not used a male 3/4
NPT pipe, coupling or thread to sweat adapter
shall be 1/2 an inch beyond the finished face of
the wall.
HYDRONIC HOOK-UP
Hydronic Towel
Warmer
Supplied with
Towel Warmer
Field Supplied
Eccentric
coupling
(optional)
Straight
coupling
(or similar)
Field Plumbing
Escutcheon
Washer
Valve
Union
STEP 3: INSTALLATION
A. Mounting:
1. The Mr.Steam Towel Warmer has been designed with
integral mounting brackets. These will facilitate a permanent
and secure mounting of the Towel Warmer to the wall using
the screws provided.
2. Locate the brass inserts according to the following chart:
(All inlet/outlet pipes are 18 1/2” apart.)
3. Slide a bracket escutcheon (with the ‘O’ ring facing the towel
warmer) on each of the mounting brackets.
4. Slide the towel warmer on the brass inserts and tighten the set
screws on both brackets. Slide the escutcheons against the
wall to hide the joint.
5. The recommended location for optional lower brackets is on
the bottom rung of the Towel Warmer, a sufficient header
should be provided for these brackets.
Vertical Distance from Inlet/Outlet Pipe centerline
H542 6-7/16”
Towel
Warmer
Union
Washer
Valve