37
Operations
Description, Specifications, Installation, and Operation Manual
Federal Signal
www.fedsig.com
User Programs
The UVRI-B has the capacity to store functions for specific alerting configuration. Use
functions to activate relays for control of external devices and activation of pre-recorded
messages. See the Commander Software Manual and the Informer-IP Setup, Program,
and User Manual.
Status Monitoring
The UVRI-B provides system monitoring with automatic or manual reporting of system
operation and status. The following items are monitored:
• System operation
• Audio Output
• Input voltage
• Charger/battery status
• Intrusion
• Local activations
Connectors, Configuration Jumpers, Test Points, Controls and Indicators
The following table provides settings and interface inputs and outputs for the control card.
Table 20 Connectors on the Control Board (See Figure 9)
J1
Microphone jack (Part Number MNC-MC)
10 kΩ input impedance,
50 mV
p-p
nominal input level
J2
Options Connector:
1-2
Enable Ethernet Port
9-10 Change Serial ports 1 and 2 from 1200 baud to 115200 and 9600
baud Respectively.
JP5 and JP4 Transceiver #1 and #2 Ports
JP6 (Line C) 10 V/25 V, 0.7 W Audio output (to Amp JP3 Audio Input)
JP7
microSD FLASH card holder
JP8
600 Ω I/O Control and PA Input
Siren and TX Audio Output – Balanced
Typically used with landline application
TC1 Output
600 Ω Audio Signal
TC1 Input
600 Ω Audio Sense
JP9
600 Ω Audio Sense Input – Balanced
Jumpered to JP10 when not used
Typically used for fire panel interface
JP10
600 Ω Audio Signal Output – Balanced
Typically used for fire panel interface