BLUE 18 AWG
100 W (SSP2000B/SSP3000B)
200 W (SSP3000B ONLY)
BROWN 18 AWG
SERIAL PORTS
10 8 6 4 2
9
5
7
3 1
AUX
2 3
3
4
4
5 6 7 8
1
11 1 1 1 1
2
2 3 4
AUX
PARK
INPUT
+12V
+
P
RADIO
RING
SPKR
DO NOT EXCEED 5 AMPS
MAXIMUM ON HORN RING
CIRCUIT. SEE INSTALLATION
INSTRUCTIONS
RADIO
RING
SPKR
RADIO
RING
SPKR
RADIO
RING
SPKR
SM
Quick Connect Guide: SSP3000B/SSP2000B System Wiring Connections
25500152 REV. A0 1014
SERIAL PORTS: Connect
up to two Federal Signal
serially-controlled devices.
SPEAKERS: Two are
connected in parallel
and in phase (SSP3000B).
SSP2000B has only one
speaker.
For details, see the "SmartSiren Platinum Series Installation, Maintenance,
and Service Manual" (P/N 25500151) and the "Convergence Network
Configuration Software Manual" (P/N 2562418).
MICROPHONE
(P/N 258B577-03)
SM
1
SM
2
SM
3
SM
4
SM
5
SM
6
SM
7
SM
8
8-HEAD
S
IGNAL
M
ASTER
6-HEAD
S
IGNAL
M
ASTER
S
M POWER OUT (20 A
FUSE ON TOP OF SIREN)
11 12 13 14 1
2
3
4
AUX. RELAYS
INPUTS
WHITE
BROWN
GREEN
ORANGE
VIOLET
YEL
LOW
GR
AY
BLUE
WHT/RED
WHT/ORG
WHT/YEL
WHT/BLU
WHT/BRN
WHT/GRN
WHT/V
LT
WHT/G
R
Y
SM SM SM SM SM SM
1
2
3
4
5
6
20 AWG
RED 18 A
WG
BLACK
AUX. RELAYS 11-14:
2
A solid-state relays
are 12
Vdc out only.
For these two connectors
(P/N 1751541 and P/N 1751542-01)
see the enlarged detail on the right.
RELAY CABLE ASSY.
(P/N 1751541)
10
8
6
4
2
9
7
5
3
1
WHITE
BROWN
GREEN
BLUE
RED
ORANGE
YELLOW
VIOLET
GRAY
BLACK
18 AWG
AUX. RELAY 1–10:
10 A solid-state relays 9/10
can be configured as 12 Vdc
out or ground out. Relays 1-8
are 12 Vdc out. The SSP2000B
has only relays 1-6 and 10.
INPUTS 1–2:
Apply ground
to activate.
INPUTS 3–4:
Apply 12 Vdc
to activate.
PARK INPUT (BLACK):
Sends a signal to the siren
amplifier that:
• mutes all siren tones except
Air Horn and Manual
OR
• disables white flashing lights
when the vehicle transmission
is shifted into park or neutral.
HORN RING: Enables the
step-through selection of
siren tones each time the
horn ring is pressed while
the control of the tone is
transferred.
Back of SSP3000B Siren Amplifier / Relay Module
FS
C
onvergenCe
™
NETWORK
CONNECTIONS
(to serially-
controlled devices)
ACTIVE-LOW INPUTS 1-4:
Ground-activated. Can be
programmed to activate with the
control pad, installer-supplied
switches (current capacity of
100 mA each), or with the two-
position switches on the steering
wheel of the Ford Police Interceptor.
RADIO: Rebroadcasts
incoming radio messages
through the siren speakers.
6-PIN CABLE ASSY.
(P/N 17500307):
See connector detail below.
BLACK
RED
INPUT 4 (BLUE)
INPUT 3 (PURPLE)
INPUT 2 (WHITE/YELLOW)
INPUT 1 (GRAY)
TO -GND
TO +12 V CONNECTION
ACTIVATED BY IGNITION (OR
TO +BAT IF THE IGNITION
TIMER FUNCTION IS USED)
IGNITION INPUT (YELLOW)
IF THE IGNITION TIMER
FUNCTION IS USED
22 AWG
FS
C
onvergenCe
NETWORK CONNECTION
CABLE, 25 FEET LONG (P/N 1751357-02)
ETHERNET
CABLE ASSY.
(P/N 1751532)
CONTROL PAD CABLE
ASSY. (P/N 17500308)
Computer for the
software configuration
of the siren system.
S
ignal
M
aSter
™, RELAY and INPUTS
CABLE ASSY. (P/N 1751542-01)
+
–