Configuring the External Relay
85
SmartSiren Platinum Series
Configuring the External Relay for the Slide Switch Buttons
1.
Click a
Slide Switch
button.
NO
TE
Button Function Limits
The functions for all buttons (except
Slide Switch 3
, which accepts a limit of 20)
are limited to a maximum of 10.
2.
If the
External Relay
pane is not in front of the other
Device Selection
panes, click the
External
Relay
tab.
3.
Select a relay for configuration. The relay is highlighted so that you can easily see it for editing.
The other relays dim until you complete the configuration of the relay by selecting the options on
the right. For a description of the options, see the tables on pages 75 and 76.
Relays are available when
Activate Relays 3 and 4 into
2-Channel Flasher
is not selected.
Option for small flashing lights
connected to Relays 3 and 4.