background image

17

Installation

Description, Specifications, Installation, and Service Manual

 

Federal Signal 

www.fedsig.com

To mount the siren on the Class 2 utility pole using the three-foot-long angle iron legs:
1.  Uncrate the siren and remove the nuts that hold the siren on the shipping base. In-

stall drivers if needed. Lift the siren approximately 3-1/2 feet with a crane or hoist.

 

NOTE: To protect the speaker arrays from damage during shipping, all models have 

been shipped without drivers installed.

2.  If you ordered optional top and side lights, see “Installing Lights on the Siren” on 

page 22. You may want to install the lights before placing the siren onto the pole.

3.  Install the four legs on the siren mounting plate, as shown in “Figure 2 Siren Leg As-

sembly” on page 15. Use two stainless steel 1/2-inch bolts, nuts, and lock washers 

(provided) for each leg. All mounting hardware needed is supplied in the hardware kit 

shipped with this manual. Do not tighten the bolts completely.

 

INSTALLATION PRECAUTIONS: The eyebolt does NOT have sufficient strength 

to support the combined weight of the siren and a utility pole. Therefore, do NOT 

attempt to erect the pole and siren together using the eyebolt as a lifting point.

4.  Erect the utility pole according to accepted practices and FEMA guidelines. (Refer to 

notice.) Ensure the pole extends at least 40 feet above the ground.

5.  Raise the siren to the necessary height and lower it over the pole. Maintain tension 

on lifting chain until all bolts are tightened.

6.  Adjust the legs and insert shims, if necessary, between the siren legs and pole. Bolt 

the siren to the pole using two user-supplied 5/8-inch lag bolts, at least 4 inches long, 

for each leg. Tighten all bolts, including those from step 2.

Steel Pole Mounting

In a typical steel pole-mounted siren installation, the MOD1004BC, MOD2008BC, and 

MOD3012BC sirens are mounted on a Grade A Standard galvanized steel pole. The 

MOD4016BC, MOD5020BC, MOD6024BC, MOD6032BC, and MOD8032BC are mounted 

on a Grade A Heavy galvanized steel pole. (Ensure that soil loads will conform to this 

utility pole size.) 
NOTE: The siren leg assembly is not included with the steel/concrete pole models.
To mount the siren on a Grade A Standard galvanized steel pole:
1.  Erect the steel utility pole according to accepted practices and FEMA guidelines.
2.  Uncrate the siren. Remove and dispose of any hardware that holds the siren on the 

shipping base. Install drivers. Lift the siren with a crane or hoist to the necessary 

height and lower it over the pole. Maintain tension on the lifting chain until all bolts 

are tightened.

3.  If you ordered optional top and side lights, see Installing Lights on the Siren. You 

should install lights before placing the siren onto the poll.

Содержание MOD Series

Страница 1: ...ications Installation and Service Manual 25500059 Rev A3 1223 Printed in U S A Copyright 2013 2023 Federal Signal Corporation Modulator High Powered Omni Speaker Model MOD Series Shown with optional Q...

Страница 2: ...all 1 708 534 3400 This limited warranty is in lieu of all other warranties express or implied contractual or statutory including but not limited to the warranty of merchantability warranty of fitness...

Страница 3: ...Pole Mounting 15 Steel Pole Mounting 17 Flat Surface Mounting 19 Driver Connections 19 Installing Lights on the Siren 22 Installing the Top Light Kit 22 Installing the Side Light Kit 23 Pre Operation...

Страница 4: ...MOD3012B 11 Table 7 MOD4016B 11 Table 8 MOD5020B 12 Table 9 MOD6024B 12 Table 10 MOD6032B 12 Table 11 MOD8032B 12 Table 12 Sound levels predictions 13 Table 13 Number of Wires and Cable Length per Mod...

Страница 5: ...0 Nuclear Plant Guideline Planning If suitable warning equipment is not selected the installation site for the siren is not selected properly or the siren is not installed properly it may not produce...

Страница 6: ...ise control ordinances as well as OSHA noise exposure standards regulations and guidelines After installation or service test the siren system to confirm that it is operating proper ly Test the system...

Страница 7: ...death or serious injury WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a hazardous situation which if not avoided could result...

Страница 8: ...l electronic Modulator Series siren consists of aluminum modules that use four 100 watt drivers per module The Modulator series B is available in several models with the following sound output rating...

Страница 9: ...roduction 360 coverage without sound variation in horizontal planes Easy servicing through convenient access panels Anechoic chamber certified Optional visual signaling options that enhance the Modula...

Страница 10: ...able Length per Module on page 20 The extension cable is also available in 10 foot increments Mounting the UV controller farther than 100 feet is not recommended Farther mounting may decrease the powe...

Страница 11: ...ker Array 38 91 inches 98 83 cm Weight 190 lb 86 18 kg EPA at 40 feet 12 19 m 4 94 ft2 0 46 m2 Wind Load 110 mph 40 feet above ground 378 lb 171 46 kg Table 6 MOD3012B Number of Active Modules 3 Power...

Страница 12: ...Array 94 37 inches 239 70 cm Weight 450 lb 204 12 kg EPA at 40 feet 12 19 m 11 54 ft2 1 07 m2 Wind Load 110 mph 40 feet above ground 882 lb 400 07 kg Table 10 MOD6032B Number of Active Modules 6 Power...

Страница 13: ...ditions the terrain obstructions in the sound path the pitch of the sound and the height of the siren Optimum sound propagation conditions occur when no obstructions exist in the sound path the terrai...

Страница 14: ...alling a siren possible in almost any situation If the installations in this section are unsuitable modifying one of the configurations may be practical A siren is typically installed 40 to 50 feet ab...

Страница 15: ...nted siren installation is shown in Figure 3 The siren is mounted on a Class 2 utility pole ANSI type wooden pole or equivalent with a minimum horizontal ground stress rating of 3 700 pounds 1678 kg E...

Страница 16: ...Y REQUIRE GUYING FOR THE POLE CLASS II UTILITY POLE CUSTOMER SUPPLIED CUSTOMER SUPPLIED GROUND ROD TO BE 8 FT 4 COPPER WITH CLAMP 1 1 4 CRANE LIFT HOLE CONTROL UNIT BATTERY BOX ULTRAVOICE CONTROL CONT...

Страница 17: ...and FEMA guidelines Refer to notice Ensure the pole extends at least 40 feet above the ground 5 Raise the siren to the necessary height and lower it over the pole Maintain tension on lifting chain un...

Страница 18: ...EAVY NOTE TO AVOID GALVANIC CORROSION INSTALL RUBBER INSULATOR 8570080 BETWEEN SIREN BASE PLATE AND POLE BASE PLATE USE S S SHIMS BETWEEN MTG PLATES IF MATING SUFACES ARE NOT FLUSH TO AVOID WELDMENT C...

Страница 19: ...nd wire colors will vary This is due to the different number of drivers required for each model See Figures 6 and 7 for wiring and position Observe proper polarity when making these connections The st...

Страница 20: ...2 For the standard cable length supplied with the siren see Table 13 The number of conductors and colors varies from module to module For example in a MOD5020B there are 16 wires with only 10 of those...

Страница 21: ...ED BLK BRN WHT WHT BRN WHT ORG 1 2 3 4 5 6 ACTIVE MODULE DRIVER TERMINAL A2 2 A4 1 C1 1 DRIVER TERMINAL A3 2 A1 1 A1 2 A2 1 A3 1 A4 2 WHT RED RED RED WHT WHT RED WHT B2 2 B4 1 B3 2 B1 1 B1 2 B2 1 B3 1...

Страница 22: ...Light Kits NOTE The standard light referenced is red but other colors are available The following instructions refer to the configuration of the Modulators that have been preconfigured Installing the...

Страница 23: ...from the wire harness within the module Connect the wires four red and one pink positive together with a wire nut Connect the black wires five black negatives together with a wire nut Zip tie the wir...

Страница 24: ...AZARD Service or maintenance should be performed by qualified personnel familiar with the siren associated controls and power sources being used The sound output of sirens is capable of causing perman...

Страница 25: ...tiple drivers are defective or a wire has been severed The impedance of a single driver should be 2 25 ohms To determine the location of the defective driver see Figure 6 Driver Connections on page 20...

Страница 26: ...eaker Model MOD Series Federal Signal www fedsig com Ordering Parts To order replacement parts call customer support Table 16 Replacement Parts Description Part Number Top Light Kit 191XL 024R Side Li...

Страница 27: ...ng Technical Support and Service For technical support contact Federal Signal Technical Support Phone 800 524 3021 or 708 534 4790 Email techsupport fedsig com www fedsig com For customer support cont...

Страница 28: ...2645 Federal Signal Drive University Park Illinois 60484 www fedsig com Customer Support 800 548 7229 1 708 534 3400 Technical Support 800 524 3021 1 708 534 4790...

Отзывы: