WINP – Wireless Input
User manual
December 2021 - Version EN 1.3
www.fdstiming.com
4.1.
Groups (radio frequencies) - Europe / India / Russia
6 Groups are available.
Group A, B, C, D:
Wireless Transmission Distance: up to 2000m (clear line of sight)
Each group uses ¼ of the full frequency band
Min locking time of 200ms
Group E, F:
Wireless Transmission Distance: up to 5000m (clear line of sight)
Each group uses the full frequency band
Those groups limit the use of 2 WINP/WIRC only
Min locking time is longer: 500ms
OFF:
The radio transmission function is disabled.
4.2.
Groups (radio frequencies) - North America / Japan
8 Groups are available
Group A, B, C, D:
Tested wireless Transmission Distance (clear line of sight)
US
: up to 4000m
Japan : up to 1000m
Min locking time of 200ms
Group E, F, G, H:
Tested wireless Transmission Distance (clear line of sight)
US
: up to 6000m
Japan : up to 1500m
Those groups limit the use of 2 WINP/WIRC only,
Min locking time is longer: 500ms
OFF:
The radio transmission function is disabled.