In cases where the barrel connector is not desired, you can use the alternate power input connector
(J8) with supports directly plugging in 20-26 AWG wire with maximum 5A current per contact. The
datasheet for this J8 connector (PCB terminal block - PTSM 0,5/ 2-2,5-H SMD WH R24 – 1814634)
can be found at
To verify that the ELI70-INHW unit is correctly powered you may check the 12VDC input with a
Fluke meter or scope by probing the +12V and GND contacts shown below. Please verify that the
12VDC is present, is within the +/- 5% tolerance and is free from excessive noise or AC ripple.
Figure 4. ELI70-INHW Power Test Points