FDC ENIGMA II SLIMLINE SLIDE Скачать руководство пользователя страница 2

LT4935 (1:01/08) 

2

ENIGMA II SLIMLINE SLIDE 

Owner's Manual 

 

CONTENTS 

 

 

 

 

 

 

 

 

 

 

 

 

PAGE 

USERS INSTRUCTIONS

 

 

SECTION ONE 

Important Information

   

 

 

 

 

 

 

SECTION TWO 

Operating the Appliance

 

 

 

 

 

 

 

SECTION THREE 

Fuel Bed Layout

 

 

 

 

 

 

 

 

SECTION FOUR 

Cleaning

   

 

 

 

 

 

 

 

 

SECTION FIVE 

General Points

   

 

 

 

 

 

 

10 

 

INSTALLATION INSTRUCTIONS

 

 

SECTION SIX 

Appliance Data

 

 

 

 

 

 

 

 

11 

 

SECTION SEVEN 

Regulations & Warnings

   

 

 

 

 

11 

 

SECTION EIGHT 

Siting the Appliance

  

 

 

 

 

 

13 

Class One 

 

 

 

 

 

 

 

 

 

13 

Class Two Pre-cast 

 

 

 

 

 

 

 

 

13 

Class Two Fabricated Metal 

 

 

 

 

 

 

 

14 

Clearance to Shelf or Surround 

 

 

 

 

 

 

14 

Clearances at Side of Fire 

 

 

 

 

 

 

 

14 

 

SECTION NINE 

To Install the Appliance

 

 

 

 

 

 

15 

Checking the Flue and Fire Opening   

 

 

 

 

 

15 

Connecting the Gas Supply 

 

 

 

 

 

 

 

15 

Fixing Back to Opening 

 

 

 

 

 

 

 

16 

Optional Cable Fixing System  

 

 

 

 

 

 

17 

Gas Soundness Test   

 

 

 

 

 

 

 

17 

Check Burner Pressure and General Operation 

 

 

 

 

18 

 

SECTION TEN 

Checking Operation of Fire

   

 

 

 

 

19 

Checking Product Clearance   

 

 

 

 

 

 

19 

Fit Fire Front and Trim  

 

 

 

 

 

 

 

19 

Advise Customer  

 

 

 

 

 

 

 

 

19 

 

MAINTENANCE INSTRUCTIONS

 

 

SECTION ELEVEN 

Maintenance

  

 

 

 

 

 

 

20 

Replacement of Gas Control   

 

 

 

 

 

 

20 

Replacement of Injector 

 

 

 

 

 

 

 

21 

Replacement of Silencer 

 

 

 

 

 

 

 

21 

Replacement of Oxy-Pilot Assembly   

 

 

 

 

 

21 

 
 
 
 
 
 
 
 

Содержание ENIGMA II SLIMLINE SLIDE

Страница 1: ...LIMLINE SLIDE OWNER S MANUAL Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in GREAT BRITAIN or IR...

Страница 2: ...ass Two Fabricated Metal 14 Clearance to Shelf or Surround 14 Clearances at Side of Fire 14 SECTION NINE To Install the Appliance 15 Checking the Flue and Fire Opening 15 Connecting the Gas Supply 15...

Страница 3: ...Use disposable gloves facemasks and eye protection After handling wash hands and other exposed parts If a vacuum is used for cleaning the coals or cleaning after servicing installation it is recommend...

Страница 4: ...low the lever to spring up the pilot light should remain alight and the main burner should light on its low setting c Should the pilot fail to light pull the lever fully up to turn off the appliance w...

Страница 5: ...BED Some soot deposits will form on the coals this is perfectly normal and adds to the realism of the appliance USE ONLY THE COALS PROVIDED AND NO ADDITIONAL COALS MUST ADDED The Loose coal set consis...

Страница 6: ...ge to coals to have rough sides forward and make sure that they are stable in their positions Place five coals between the first row of coals and the rear matrix as shown Arrange them to look as rando...

Страница 7: ...louration of the firebox sides is also perfectly normal and does not detract from the operation of the fire USE ONLY THE PEBBLES PROVIDED NO ADDITIONAL PEBBLES MUST ADDED The Loose pebble set consists...

Страница 8: ...beige colours to give a pleasing layout Place the second row of five large pebbles as shown Again mix the colours Place the top row of four pebbles on top of the rear matrix as shown Place the three...

Страница 9: ...taken to avoid contact with the refractory lining this is a delicate surface and should not be wiped or rubbed A vacuum cleaner may only be used after all the loose coals have been removed SECTION FI...

Страница 10: ...dard Assessment Procedure SAP for energy rating of dwellings PACK CONTENTS Refractory Fuel Bed Components Appliance Rear Matrix Owners Instruction Front Matrix Wire Fixing Kit Loose Coals Foam Seal Tr...

Страница 11: ...ABLE ITEM AND MUST BE EXCHANGED AS A COMPLETE ASSEMBLY USING ONLY THE ORIGINAL MANUFACTURER S PART A non combustible hearth must be provided to comply with the building regulations or a suitable propr...

Страница 12: ...debris collection Any permanent flue restriction or variable dampers shall be removed or locked fully open The chimney should be swept prior to installation if not new or previously used with a gas ap...

Страница 13: ...a good seal is formed between the rear and base of the appliance and the chimney to avoid any reduction of natural draught A non combustible hearth must be provided beneath the appliance within the fi...

Страница 14: ...e the gas supply is to be connected to the appliance This may be done from the front of the unit from either the left or right side or a concealed fitting from the rear Check that the restrictor elbow...

Страница 15: ...eing used fix the spacer box to the fireplace first with wood screws and wall plugs then screw firebox to spacer box using screws provided Cut a cross slit in the rubber grommet and feed the appliance...

Страница 16: ...openings or when it is desirable not to drill the fireplace fascia It may not be possible to use the cable fixing system with some pre cast flues Drill 4 holes in the rear of the fireplace opening in...

Страница 17: ...osition and allow the appliance to run for approximately 5 minutes Check the inlet pressure is 20 1 mbar Fuel Bed Layout IMPORTANT REFER TO THE HEALTH SAFETY NOTICE LOCATED ON PAGE 3 OF THIS BOOKLET B...

Страница 18: ...room opened and the extractor fan running at maximum setting Should spillage occur seek expert advice Fit the fire front and trim Fit the trim front with the 4 magnetic strips placed on the vertical...

Страница 19: ...t to damage the pilot head Replacement of Gas Control 1 Turn off the gas supply by the isolating cock 2 Remove fire fret 3 Remove all Loose coals or Pebbles 4 Remove moulded refractory parts 5 Remove...

Страница 20: ...ning or replacement 4 Re assembly is the reverse of removal Replacement of Oxy Pilot Assembly NOTE If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer...

Страница 21: ...LT4935 1 01 08 21...

Страница 22: ...e found on the label attached to the packaging and on the data badge which is located on the appliance flange top right behind trim Retailer Name ___________________________________________ Address __...

Страница 23: ...__________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model Enigma II Slimline Slide Serial No Date of Purchase This information can be found on the label attached...

Страница 24: ...y Warning Label Fire Guard Warning Label Fire Guard Bag Loose Coals 4795 Loose Pebble Set 4792 Rear Matrix Coal 4794 Rear Matrix Pebble 4791 Front Matrix Coal 4793 Front Matrix Pebble 4790 Magnet Segm...

Отзывы: