5.0  Technical  Data 

–  Declaration  of  Performance 

(DoP) 

 
Manufacturers authorised Representative:

 FDC UK Ltd, Dinton Business Park, Dinton, Salisbury, SP3 5HZ.  

Manufactured By: 

Charlton & Jenrick Ltd, Telford, TF3 3AR 

Range Designation:

 FDC Freestanding Range  

Models:

 FDC 4/5/5W/8 with nominal outputs of 4kW, 5kW, 5kW and 8kW. 

Intended Use: 

Domestic heating appliances without supply of hot water.

 

Independently Performance & Safety tested by:

 Kiwa Gastec, Notified Body No: 0558, Certificates & Reports 

issued. 

Constancy of Performance System:

 ISO9001, System 3. 

 

The performance of the products identified above is in conformity with the declared performance in the table. 
 

 

Peter Mintoft 

Director, Charlton & Jenrick Ltd 

October 2014 

 

 Model  

FDC 4 

FDC 5 

FDC 5W 

FDC 8 

Domestic Heating 

Appliances 

 

Appliance gross weight 

(packed) (Kg): 

54 

70 

74 

81 

 

 

Harmonized Test Standard 

EN13240: 2001 Amd 2: 2004 

 

 

Quality Constancy Standard 

ISO9001 

 

 

Test Report Issue No 

6546-2 

6546-3 

6946 

6546-4 

 

 

Efficiency on wood fuel: (%)   

78 

81.5 

79.0 

78.6 

 

 

Declared nominal output: 

(kW)  

4.0 

5.0 

5.0 

7.6 

 

 

Tested wood re-fuelling 

interval: (h) 

0.75 

1.5 

0.75 

 

 

Flue gas mass flow on wood 

fuel: (g/s) 

3.9 

3.5 

5.1 

5.8 

 

 

*Flue Temp on wood fuel: 

(Deg C) 

235 

250 

229 

302 

*at nominal heat output

 

 

Max Log Length:  

300mm 

12” 

 300mm 

12” 

375mm 

14.5” 

 375mm 

14.5” 

 

 
 

Efficiency on Ancit fuel: (%)   

82.4 

82.1 

74* 

77.1* 

*With DEFRA air limiter fitted 

– approx. 80-81% without. 

 

Declared nominal output on 

Ancit Fuel: (kW)  

4.0 

5.0 

5.0 

7.9 

 

 

Tested Ancit re-fuelling 

interval: (h) 

 

 

Flue gas mass flow on Ancit 

fuel: (g/s) 

2.7 

2.7 

4.5 

4.0 

 

 

*Flue Temp on Ancit fuel: 

(Deg C) 

205 

239 

276 

300 

*at nominal heat output

 

 

Safety Distances from Combustibles

 

 

Side Wall (mm): 

500 

700 

600 

750 

 

 

Rear Wall (mm): 

750 

800 

800 

850 

 

 

 

 

 

 

 

 

 

Содержание 4

Страница 1: ...n order to ensure compliance at all times FDC 4 5 5 Wide 8 FREESTANDING STOVE RANGE 4 5 5 8 kW Nominal Outputs With Patented TTi Air System Installation and Operating Instructions Please hand these in...

Страница 2: ...lation Information 4 4 1 Chimney 4 4 2 Ventilation 5 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 5 4 6 Hearths 6 4 7 Commissioning Handover 6 5 Technical Data Declaration of...

Страница 3: ...t of Components section and check contents carefully 2 1 To remove the baffle plate first remove the two stainless steel side firebox liner clips by lifting them above the fuel retainer Remove the two...

Страница 4: ...nd BS EN 15287 must be fulfilled The installation is a notifiable building works as defined in the building regulations and that it is a legal requirement under England and Wales Building Regulations...

Страница 5: ...possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment 3 1 11 Metal Parts When installing or servicing this...

Страница 6: ...tted be used on the FDC 5 5W models ONLY providing that they only burn smokeless fuel or seasoned wood logs with the air limiter fitted in in full accordance with the wood burning instructions An exis...

Страница 7: ...nding stoves do not require a constructional hearth beneath them as they do not cause the floor temperature to exceed 100 degrees C Note the optional solid fuel hearth heat shield MUST be fitted when...

Страница 8: ...and ensure that the operating instructions and operating tools including gloves for the stove are left with the customer You must be sure to advise the customer on the correct use of the appliance wit...

Страница 9: ...5 FDC 5W FDC 8 Domestic Heating Appliances Appliance gross weight packed Kg 54 70 74 81 Harmonized Test Standard EN13240 2001 Amd 2 2004 Quality Constancy Standard ISO9001 Test Report Issue No 6546 2...

Страница 10: ...nce exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or ex...

Страница 11: ...the pointed part of the multi tool into the knob and lifting up and down or pulling and pushing the knob depending on the model The grate is a strong set of cast iron bars with suitable air slots that...

Страница 12: ...ill then control the burn rate of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning After re fuelling open the air wash full for 3 to 5 minutes o...

Страница 13: ...open the secondary air wash control fully Then load the firebox with plenty of starting fuel i e paper dry kindling sticks and or firelighters If using Ancit place a layer of ancit into the firebox a...

Страница 14: ...the controls are left in this position the fire will eventually go out If you want to revive the fire it is recommended that the primary air controls are open first and then open the secondary air co...

Страница 15: ...Open doors and windows to ventilate room and then leave the premises 2 Let the fire out or remove and safely dispose of fuel from the appliance 3 Check for flue chimney blockage and clean if required...

Страница 16: ...15 FDC 4 5 5W 8 Issue 05 10 14 8 1 FDC 4 Stove Dimensions...

Страница 17: ...16 FDC 4 5 5W 8 Issue 05 10 14 8 2 FDC 5 Stove Dimensions...

Страница 18: ...17 FDC 4 5 5W 8 Issue 05 10 14 8 3 FDC 5W Stove Dimensions...

Страница 19: ...18 FDC 4 5 5W 8 Issue 05 10 14 8 4 FDC 8 Stove Dimensions...

Страница 20: ...ur local Stove retailer will be pleased to supply spare parts and to provide any other information you require Alternatively contact FDC direct 7 Can the doors be left open while burning For safety an...

Отзывы: